Installation, use and maintenance manual
46
DOCUMENT 6328408
3
Design characteristics
1
Heat pump.
2
Control panel.
3
Embossed ABS casing.
4
Enamelled steel tank (boiler) in compliance with
UNI standards (260-litre capacity).
5
Upper boiler probe.
6
Lower boiler probe.
7
Refrigerant refill input.
8
Ambient air recirculation fan.
9
Thermal expansion valve.
10 High-efficiency finned pack evaporator. The
quantity of fluid is regulated via a
thermostatic valve.
11 Ventilation air input (
160 mm).
12 Ventilation air output (
160 mm).
13 Hermetic rotary compressor.
14 Replaceable magnesium anode
15 Electrical resistor
16 Capacitor delivery
17 Capacitor return
18 Replaceable magnesium anode
19 Hot water outlet connector (1”G).
20 Recirculation fitting (¾”G)
21 Input for coil for solar thermal power (1”
1/4
G;
exchange surface 1 m
2
)
22 Condensate outlet (½”G).
23 Output for coil for solar thermal power
(1”
1/4
G; exchange surface 1 m
2
)
24 Cold water inlet connector (1”G).
25 Polyurethane insulation 50 mm.
26 Safety pressure switch, automatic reset.
27 Incoming air filter
28 Sensor socket fitting ½”G
1
6
11
10
9
2
8
18
25
24
16
14
5
4
15
12
22
19
23
20
21
17
3
27
7
13
26
28