SAFETY WARNINGS AND RULES
m
WARNINGS
– After having removed the packaging,
make sure that the supplied product is
intact and complete in all its parts. If
this is not the case, please contact the
Dealer who supplied the product.
– The system must be used as intend-
ed by
Sime
which cannot be held lia-
ble for any harm caused to people or
damage to animals or objects due to
incorrect installation, adjustment or
maintenance and improper use of the
appliance.
– In order to ensure optimal efficiency
of the product,
Sime
recommends per-
forming maintenance and check on an
ANNUAL
basis.
–
All operators are advised
to read this
manual carefully in order to use the
appliance in a safe and logical manner.
– In agreement with the end user of the
appliance, consider all the details that
guarantee safe and correct installa-
tion. These details refer to the selec-
tion of the installation position, the di-
rection, the arrangement of piping, the
suitable surface area, etc.
– The installation position must not be
under the shade of trees or other ob-
stacles throughout the entire year.
– The product’s installation must con-
form to the local electrical and plumb-
ing regulations.
– For optimal efficiency, the appliance
should be facing southwards in the
northern hemisphere and the oppo-
site way in the southern hemisphere.
Should this not be possible, it can be
positioned 30° East if DHW is request-
ed before 14:00 or 30° West if DHW is
requested after 14:00. In both cases,
the thermal loss will not exceed 6%
per year.
m
WARNINGS
– If the system is positioned on a roof
with a pitch below 15° or above 30°,
another type of equipment must be
used instead of the standard support
frame.
– For installation on pitched roofs, the
frame must be positioned by ensuring
that the water tank lies exactly above a
horizontal support and never between
two pillars.
– If the surface on which the appliance
will be installed is not compatible with
the standard equipment supplied, spe-
cial components must be used.
– The device must be chosen and in-
stalled by the installer in agreement
with the end user.
– When the appliance must be installed
on a pitched roof, the brackets must
be fastened with bolts guaranteeing
correct and safe installation.
– In areas subject to heavy snowfall, it
is very important to ensure that snow
does not accumulate behind the wa-
ter tank and that the standard frame
is able to withstand the weight of the
snow.
– Special care must also be taken when
installing the appliance in areas sub-
ject to extremely windy conditions.
– The pipes of both the solar unit and the
cold/hot water for the building must
be adequately insulated.
– Only qualified technicians must fill
the closed circuit and connect it. Be-
fore the closed circuit is filled with
the heat-transfer fluid, the water tank
must be completely filled.