2.12 Electrical connections
The boiler is equipped with a ready wired power cable which is
to be connected to a 230V~50 Hz network.
If this cable needs to be replaced, an original spare must be
requested from Sime.
Therefore only the connections of the original components as
shown in the table are needed. These are to be ordered sepa-
rately from the boiler.
DESCRIPTION
CODE
External sensor kit (ß=3435, NTC 10KOhm at 25°C)
8094101
Power cable (dedicated)
6323875
Remote control CR 63 (open therm)
8092219
Remote control CR 73 (open therm)
8092226
Remote control CR 83 (open therm)
8092241
Remote control HOME (open therm)
8092280
Remote control HOME PLUS (open therm)
8092281
m
CAUTION
The maintenance interventions described must
ONLY be carried out the professionally qualified per-
sonnel.
a
DANGER
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance
are touched.
OFF
Fig. 18
To facilitate introduction of the connection wires of the option-
al components into the boiler:
– remove the two screws (1), pull the front panel (2) forwards
and release it from the top by lifting it
1
2
Fig. 19
– remove the screws (3) securing the control panel (4)
– move the panel (4) upwards (a) but keeping it in the side
guides (5) to the end of travel
– bring it forwards and down (b) until it is horizontal
3
a
b
5
4
Fig. 20
– insert the connection wires into the cable gland (6) and the
opening (7) on the control panel
6
7
Fig. 21
– bring the control panel (4) to the original position and se-
cure it with the screws (3) which were removed previously
– connect the component wires to the terminal board (8) fol-
lowing the indications provided on the data plate (9).
3
4
8
9
3
Fig. 22