2.12.1 Coaxial duct
Coaxial accessories
Description
Code
Ø 60/100
mm
Ø 80/125
mm
Coaxial duct kit
8096250
8096253
Extension W. 1000 mm
8096150
8096171
Extension W. 500 mm
8096151
8096170
Vertical extension W. 140 mm with
smoke analysis take-off point
8086950
-
Adapter for Ø 80/125 mm
-
8093150
Additional 90° curve
8095850
8095870
Additional 45° curve
8095950
8095970
Tile with joint
8091300
8091300
Roof outlet terminal W. 1284 mm
8091205
8091205
Load loss - Equivalent lengths
Model
Leq (linear metres)
Ø 60/100
mm
Ø 80/125
mm
90° curve
1,5
2
45° curve
1
1
Minimum-Maximum Lengths
Model
Duct Length Ø 60/100
Duct Length Ø 80/125
W Hori-
zontal (m)
H Vertical
(m)
W Hori-
zontal (m)
H Vertical
(m)
Min. Max. Min. Max. Min. Max. Min. Max.
Brava One
HE 25
-
6
1,3
8
-
12
1,2
15
Brava One
HE 30
-
5
1,3
7
-
10
1,2
13
2.12.2 Separate ducts (split pipe system Ø 80mm)
Constructing outlets for separate ducts indicates the use of
the "air-smoke split pipe system". This is to be ordered se-
parately from the boiler and when connected to the other ac-
cessories, from those listed in the table below, completes the
smoke-outlet/ combustion air inlet assembly.
Separate accessories
Description
Code
Diameter Ø
60 (mm)
Diameter Ø
80 (mm)
Air-smoke split pipe system (without
take-off point)
8093060
-
Air-smoke split pipe system (with
take-off point)
-
8093050
90° curve M-F (6 pieces)
8089921
8077450
90° curve M-F (with take-off point)
8089924
-
M-F 80/60 reduction
8089923
-
Extension W. 1000 mm (6 pieces)
8089920
8077351
Extension W. 500 mm (6 pieces)
-
8077350
Extension W. 135 mm (with take-off
point)
-
8077304
Wall outlet terminal
8089541
8089501
Internal and external ring nut kit
8091510
8091500
Inlet terminal
8089540
8089500
45° curve M-F (6 pieces)
8089922
8077451
Manifold
8091400
Tile with joint
8091300
Roof outlet terminal W. 1390 mm
8091204
Inlet/outlet fitting Ø 80/125 mm
-
8091210
Split pipe system
1
2
3
4
Fig. 14
KEY:
1
Split pipe system with take-off point
2
Air inlet
3
Smoke outlet
4
Take-off point for smoke analysis
m
CAUTION
– The maximum total length of the ducts, obtained by
adding the lengths of the inlet and outlet pipes, is
determined by the load losses of the individual ac-
cessories used and must not exceed 15 mm H2O.
– The total extension must not in any case exceed 50 m
even if the total load loss is less than the maxi-
mum which can be applied.
Load loss accessory Ø 60 mm
Description
Code
Load loss (mm H2O)
Brava One HE 25
Brava One HE 30
Inlet
Outlet
Inlet
Outlet
Air/smoke split
pipe system
8093060
2,5
0,5
2,5
0,5
90° curve MF
8089921
0,4
0,9
0,5
1,1
45° curve MF
8089922
0,35
0,7
0,45
0,9
Horizontal exten-
sion W. 1000 mm
8089920
0,4
0,9
0,5
1,1
Vertical extension
W. 1000 mm
8089920
0,4
0,6
0,5
0,7
Wall outlet ter-
minal
8089541
_
1,2
_
1,4
Wall inlet terminal 8089540
0,5
_
0,8
_
Roof outlet termi-
nal (*)
8091204
0,8
0,1
1,1
0,15
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
NB:
for the boiler to operate correctly it is necessary that a
minimum distance of 0.50 m of the duct is respected with a
90° inlet curve.