Safety thermostat trip

(fig. 5)

If  the  safety  thermostat  trips,  the  red

"35°C"

led will start flashing. In order to

attempt  a  boiler  restar t,  rotate  the
selector knob to position ( ) and release
immediately, returning it to the  summer
(

) or winter (

) position. 

If  the  boiler  lock-out  occurs  again,  call
authorised technical staff.

Other anomalies

(fig. 6)

If  one  of  the  red

“40÷80°C”

leds  start

flashing,  switch-off  the  boiler  and  try
again. 
After  2  or  3  unsuccessful  attempts,  do
not try again, call the technical helpdesk. 

With  selector  CR/OFF/EST/INV/
RESET  of  the 

"PLANET  DEWY  90  A-

110 A"

control panel in position (

) all

the  functions  are  managed  by  the
"Logica Remote Control" regulator. 
The operating instructions are reported

inside the cover (fig. 7). 
Each setting or modification is displayed
(fig. 8).

LOGICA REMOTE CONTROL

1

6

7

8

4

5

3

2

KEY
1 Display
2 Info button
3 Operating mode button: automatic operation
4 Operating mode button: manual operation
5 Operating mode button: availability
6 Cover with instruction compartment
7 Temperature knob
8 Presence button

Fig. 7

KEY

1 Display, time
2  Heating programme
3  Unit (%/C°)
4 Presence button display
5  External temperature
6  Ambient temperature
7  Holiday function
8  Operating mode
9  Line number/day

10  Burner on

11  Heating function
12  Domestic hot water/temperature/domestic 

hot water load

Fig. 8

SPIA ROSSA INTERMITTENTE

Fig. 5

Fig. 6

SPIA ROSSA INTERMITTENTE

FLASHING RED LED

FLASHING RED LED

Содержание Benchmark

Страница 1: ...Planet Dewy 90 A 110 A User instructions GB ...

Страница 2: ... YOUR LOG BOOK ENCLOSED IS FILLED IN CORRECTLY ALL CORGI REGISTERED INSTALLERS CARRY A CORGI ID CARD BOTH SHOULD BE RECORDED IN YOUR CENTRAL HEATING LOG BOOK YOU CAN CHECK YOUR INSTALLER IS CORGI REGISTERED BY CALLING ON 01256 372300 ...

Страница 3: ... ON permanently Programming characteristics Cycle 24 hour Number of actions per cycle 96 Program time per segment 15 min Min interval between two actions 15 min TEMPERATURES ADJUSTMENT fig 2 The D H W temperature can be adju sted by turning the knob of the D H W potentiometer When there is a demand for hot water the set temperature is displayed on the red led scale from 35 80 C and the yel low dom...

Страница 4: ...the red led will light up To attempt a boiler restart rotate the selector knob to position and release it immediately placing it in the summer or winter operation position If the boiler lock out re occurs contact an authorised technical staff Insufficient water pressure fig 4 If the red 0 5 bar led starts flashing the boiler will not function to restart the operation the system must be rechar ged ...

Страница 5: ...ions are managed by the Logica Remote Control regulator The operating instructions are reported inside the cover fig 7 Each setting or modification is displayed fig 8 LOGICA REMOTE CONTROL 1 6 7 8 4 5 3 2 KEY 1 Display 2 Info button 3 Operating mode button automatic operation 4 Operating mode button manual operation 5 Operating mode button availability 6 Cover with instruction compartment 7 Temper...

Страница 6: ...played one after the other The temperature sensor continues to function independently of the display Day time ambient temperature External temperature Domestic hot water temperature This information appears only when the relative sensor is connected or if it is tran smitted by the boiler regulator Info button grey reference button The required operating mode is selected by pressing the relative bu...

Страница 7: ...re Temperature required for domestic hot water Before correcting the temperature on the regulator the thermostat valve temperatures if provided must be set to the required temperature first 1 2 3 PROGRAMMING When programming the regulator panel must be open As soon as the cover is opened the display and the functions of the buttons are switched The number in the box indicates the programme line an...

Страница 8: ...burner power and operating mode heating domestic hot water 15 16 17 Setting the time To set the day of the week 1 Monday 7 Sunday Setting the hour Setting the minutes The setting of the time will change when a full hour is reached 12 13 14 The current time is adjusted with and keeping these buttons pressed will accele rate the adjustment Select the day required for the heating phases 1 Monday 7 Su...

Страница 9: ...uthorised technical staff Safety thermostat trip Rotate selector CR OFF EST INV RESET on the PLANET DEWY 90 A 110 A control panel to the release position to reset operation fig 5 If the lock out re occurs call authorised technical staff Domestic hot water sensor fault SS Call authorised technical staff 67 68 69 70 192 193 195 Heating sensor fault SM Call authorised technical staff Insufficient wat...

Страница 10: ......

Страница 11: ......

Страница 12: ...Cod 6274211B Documentation Dpt Sime Ltd Westbourne House 80 Bagley Lane Farsley Leeds LS28 5LY Tel 0870 9911114 Fax 0870 9911115 www sime ltd uk e mail enquiries sime ltd uk ...

Отзывы: