72
External Connections
Manufacturers Instructions must be referred to when
installing boiler condensate discharge pipes
Figure 7 –
Example of a purpose made soakaway
Key
1
Condensate discharge pipe from boiler
2
Ground (this section of the condensate discharge pipe may be run either above or below
round level); End cut at 45°
3
Diameter 100 mm minimum plastic tube
4
Bottom of tube sealed
5
Limestone chippings
6
Two rows of three 12 mm holes at 25 mm centres, 50 mm from bottom of tube and facing
away from house
7
Hole depth 400 mm minimum by 300 mm diameter
8
Minimum internal diameter 19 mm
9
Pipe size transition point
10
Minimum internal diameter 30 mm
11
Water/weather proof insulation
1
2
10
5
9
4
8
3
7
6
11
October 2018 Issue 1.0
Содержание 8116902
Страница 4: ...4 ...
Страница 14: ...14 ...
Страница 52: ...52 9 EXPLODED VIEWS Frame ...
Страница 53: ...53 Hydraulic assembly ...
Страница 54: ...54 Exchanger Combustion ...
Страница 55: ...55 Control panel ...
Страница 56: ...56 Gas valve Oversleeve Fan ...
Страница 77: ...77 ...
Страница 78: ...78 ...
Страница 79: ...79 ...