SIM548C Hardware Design
RDY
GHOST MODE
+CFUN: 0
In GHOST mode, by driving the PWRKEY to a low level voltage for some time (Please refer to
the power on scenarios in 3.4.1.1), the GSM part of SIM548C will power up and go into charge
mode (charging in normal mode), all operation and AT commands can be available. In this case,
the GSM part of SIM548C will send out result code as following:
From GHOST MODE to NORMAL MODE
3.4.1.3 Turn on the GSM part using the RTC (Alarm mode)
Alarm mode is a power-on approach by using the RTC. The alert function of RTC makes the
GSM part of the module wake up while the module is power off. In alarm mode, the GSM part of
the module will not register to GSM network and the software protocol stack is close. Thus the
parts of AT commands related with SIM card and Protocol stack will not accessible, and the
others can be used as well as in normal mode.
Use the AT+CALARM command to set the alarm time. The RTC remains the alarm time if the
GSM part of the module is power down by “AT+CPOWD=1” or by PWRKEY pin. Once the
alarm time is expired and executed, the GSM part of the module will go into the Alarm mode. In
this case, the GSM part of the module will send out an Unsolicited Result Code (URC):
RDY
ALARM MODE
During alarm mode, use AT+CFUN command to query the status of software protocol stack; it
will return 0 which indicates that the protocol stack is closed. Then after 90s, the GSM part of the
module will power down automatically. However, during alarm mode, if the software protocol is
started by AT+CFUN=1 command, the process of automatic power down will not be available. In
ALARM mode, driving the PWRKEY to a low level voltage for a period will cause the GSM part
of the module to be powered down (Please refer to the power down scenario ).
The table follow briefly summarizes the AT commands that are used usually during alarm mode,