Finish:                                                Acrylic Enamel 
 
Weight:                        7.0 kg 
 
Size:                          63 cm(L) x 9.0 cm(H)x17 cm(W) 
 
Bench Stand Feet:              Nonconductive, Nonstaining Polymer 
 
Optional Air Filter:           30 PPI Open Cell Polyurethane Foam 
Ion Balance (offset voltage):    OV ±15V 
 
Lamp:                                                    9 watt twin tube 
Ion Output(discharge time: S) 

 

       

                            300mm              300mm          300mm            300mm 

 

 

                   

 

                                         

Tp1

 

5.5      

tp5

  8.5     

tp9

    11.0         

tp13

  15 

                                                                                                                                          300mm 

 

                                         

Tp2

 

1.5      

tp6

  3.5     

p10

  7.0      

tp14

  11.0 

                                                                                                                                                                             

           

                                                                                                                                          300mm 

 

                                           

                                         

Tp3 

 

1.5     

tp7

  3.5     

tp11

   7.0     

tp15

  11.0                                           

                                                                                                                                          300mm 

                      blower 

                                         

Tp4

 

5.5      

tp8

  8.5     

tp12

    11.0         

tp16

  15.0 

 

                                                                                                                                           

1.

 

Offset voltage and discharge time determined as per ESD Association Standard 
No. 3 using 6’’ x 6’’, 20pF plate(charged plate monitor). 

2.

 

Discharge times are in seconds from 1000 volts to 100 volts at locations shown. 

3.

 

Above testing value can be changed with difference of temperature, humidity 
and ambient environment 

Note:

 Discharge times for high speed are 10% longer for 230 v, 50Hz. 

Содержание OVERHEAD Series

Страница 1: ...OVERHEAD is a two Fan unit designed to provide targeted coverage for electrostatic problems MATTERS FOR DAILY INSPECTION Clean high voltage needles Verify grounding connection Inspect equipment for da...

Страница 2: ...y The high voltage AC is applied to a circular arrangement of stainless steel ion emitter points which results in an intense alternating electric field at the tip of the emitter points It is this elec...

Страница 3: ...ations Unit Part Number OVERHEAD 120VAC OVERHEAD 230VAC Line Voltage 120 VAC 60 Hz 230 VAC 50Hz Current Draw Max 2 Amp 1 Amp Air Volume Output Fan Speed Flow Low 2 35 CFM High 2 70 CFM Air Velocity Fa...

Страница 4: ...3 15 300mm Tp2 1 5 tp6 3 5 p10 7 0 tp14 11 0 300mm Tp3 1 5 tp7 3 5 tp11 7 0 tp15 11 0 300mm blower Tp4 5 5 tp8 8 5 tp12 11 0 tp16 15 0 1 Offset voltage and discharge time determined as per ESD Associa...

Страница 5: ...The BLOWER OVERHEAD should be placed approximately 1 to 3 feet from the critical work area or objects to be neutralized It should be positioned to cover as much of the area as possible with the ionize...

Страница 6: ...he time required to neutralize a static charge on an item in the air stream depends on many factors Two important factors are distance to ionizer and air velocity Air ions constantly neutralize each o...

Страница 7: ...is stubborn wash the filter in mild soap and water then rinse Blot the filter dry with paper towels and allow to dry Install filter on air inlet and secure by snapping the filter retainer in place IMP...

Страница 8: ...ting value can be changed with difference of temperature humidity and ambient environment Do not try to determine ion balance by holding a static meter in the ionized air stream This will result in s...

Страница 9: ...SECTION 8 How to hang...

Отзывы: