SECTION 8  Replacement Parts/Part Numbers

Part Number

Description

4011424

minION2 (no power supply)

4011425

minION2 (with 100/120VAC Japan / North America power 
supply)

4011426

minION2 (with 230VAC Continental Europe power supply)

4011427

minION2 (with 230VAC United Kingdom power supply)

5051406

minION2 power supply only (100/120VAC Japan / North
America)

5051407

minION2 power supply only (230VAC Continental Europe)

5051408

minION2 power supply only (230VAC United Kingdom)

4371099

emitter, standard stainless steel (6 required)

4370760

emitter, long life tungsten (6 required)

4520764

modular cable, 4P4C, 3’ long

4520767

modular cable, 4P4C, 6’ long

5051141

articulated arm kit

SECTION 3  Features

• Small and compact
• Closed –loop balance control
• Simple to install and operate

SECTION 4  Specifications

OPERATING  SPECIFICATIONS

(Balance) Offset Voltage: 

0+/-10 V

Discharge time in seconds:

Distance

305 mm      460 mm        610 mm

760 mm

915 mm

(12 in.)       (18 in.)          (24 in.)

(30 in.)

(36 in.)

Fan - High

2 sec.          3 sec.

5 sec.

7 sec.

9 sec.

Fan - Low

3 sec.         4 sec.

7 sec.

9 sec.

12 sec.

Offset voltage and discharge time determined as per ANSI/ESD STM3.1 using 6”
x 6”, 20 pF plate (charged plate monitor).  Discharge times are in seconds from
1000 volts to 100 volts.

Input Power:

24 VDC, 250 mA, 6W

Power Supply: 

Universal 100-240 Vac input (IEC320) / 24 Vdc, 750
mA output, suitable to power up to 3 units.

Operating Temperature: 

0˚C to 50˚C (32˚F - 122˚F)

Airflow Volume:              

Fan - High:         42 CFM (1.2 m3/min)
Fan – Low:         21 CFM (0.6 m3/min)

Audible Noise:

52 dB(A) at 610mm (24 in.)

48 dB(A) at 1m (39 in.) 

High fan speed, measured perpendicular to air outlet.

ON/OFF:

Switch 

Fan Speed:

Variable, recessed adjustment.

Indicators:

Power: green LED, Fault: red LED.

Connectors:

Two 4-position, 4-contact (4P4C) modular “handset”
connectors for power, may also be used for daisy
chaining units. Modular cable is included with unit.
Modular connector part numbers: (Amp 5-641334-3,
Hirose TM3P-44P,  Kobiconn, 154-UL6164)