8. Maintenance
WARNING:
-
When carrying out maintenance or other work on the equipment: switch off the supply
voltage.
Operation is impaired by fouling of the bars.
Clean the bars with a hard (non-metal) brush.
Clean the bars with isopropyl alcohol when they are heavily fouled.
The other parts of the Conveyostat
®
are maintenance-free.
It will usually be necessary to dismantle the Conveyostat
®
for cleaning.
Attention:
-
Do not damage the emitter points.
-
Allow the equipment to dry properly before reusing it.
9. Faults
Problem
Cause
Remedy
No high voltage
High voltage power unit is
defective
Check the operation of the high voltage
power unit (please refer to the relevant
user’s manual)
Loose contact or cable
breakage
Check the connections and the cable
No ionisation
Fouling
Clean the bars
Conveyostat
®
not earthed or
insufficiently earthed
Earth the Conveyostat
®
properly
Table 1: Remedying faults of the Conveyostat
®
.
10. Repair
The Conveyostat
®
does not have any parts which can be repaired by the client. If the Con-
veyostat
®
is in need of repair, send it to SIMCO.
In this case, pack it properly and clearly state the reasons for return.