19-6422-M-01 Rev 4
22
3.3 Cleaning the Emitter Points
Remove power from the Blower. Normally, the emitter points can be
cleaned by using a jet of compressed air to blow off any dirt that may
have accumulated on them. A swab moistened with the IPA solution
may be used if required. If using a swab, gently wipe the tips of the
emitter points until all the dirt is removed.
Wire emitter points should not be bent or moved during cleaning.
After cleaning, make sure that the emitter wires point to the center
of the fan and are on the same horizontal plane.
The Blower uses internally-shielded emitter points that will not
normally require replacement during the normal service life of this
product. If you believe that the emitter points need to be replaced,
contact Simco-Ion Technical Support ([email protected]) for
information.
Caution:
Before performing any maintenance on emitter points, remove
power from the ionizer. Allow a minute for the high voltage
power supply to discharge.
Achtung:
Ziehen Sie vor der Durchführung von Wartungsarbeiten an
Emitter-Punkten den Netzstecker aus dem Ionisator. Lassen
Sie die Hochspannungs-Stromversorgung eine Minute
entladen.