Performax Easy/Performax Easy Speed_UM_9752152130_NL_D_GB_F_V3_1 38
5.3. Connecting the anti-static bar
Warning:
- Note the warnings at the start of this chapter.
5.3.1. Connecting the anti-static bar to the Desktop power supply
- Connect the external yellow/green wire to earth.
- Connect the cable with the M12 connector from the Desktop power supply to the anti-static
bar.
- Connect the power cable.
5.3.2. Connecting the anti-static bar to the DIN rail power supply/external power supply
- Attach the wiring as shown in Figure 5.
Figure 5: Wiring of the Performax Easy and Performax Easy Speed
For personal protection and to ensure proper functioning, the grey and the blue wire
must
both
be connected to earth.
In the Simco-Ion Desktop power supply, these connections have already been made.
6. Commissioning
Note:
- The anti-static bar does not work if the emitters are covered.
- Remove the protective cap from the anti-static bar.
The purpose of the protective cap is to protect the emitters during transport and installation.
- Switch on the power supply.
- Once a 24 V DC power supply is available and the remote on/off input has been activated,
the anti-static bar will switch on.
With a standard Performax Easy desktop power supply, the remote on/off is already connected
to the 24V power supply. If this power supply is used, the bar will therefore switch on
immediately.
blue
yellow/green or grey
brown
black
blue (GND)
yellow/green or grey
brown
black
white
white
(Cable side view)