2.6 FMS Connection
The Model 6432e Blower provides a non-isolated 4-20 mA current
loop and relay closure output for indicating alarm status to your
process equipment or facility monitoring system (FMS). In addition
to connecting 24 VDC power to the Blower, the included terminal
block (Simco-Ion p/n 18-2308) connects the Blower to the FMS
using pins 1-5.
Figure 11. FMS and 24 VDC Pins
Table 2. FMS Output Status
24 VDC process equipment power
8
-24 VDC return (Ground)
7
+24V
6
Do not use
4-20 mA current loop
5
- Current loop (Ground)
4
+ Current loop
3
Open for alarm active
Relay output loop
2
Relay common
1
Closed for active alarm
Pins
Normal State
Alarm State
No Power
Pins 1-2 (relay)
Contact Open
Contact Closed
Contact Closed
Pins 2-3 (relay)
Contact Closed
Contact Open
Contact Open
Pins 4-5 (Current Loop)
4mA (OK)
20 mA (Alarm)
0 mA (Brownout)
Содержание 6432e
Страница 1: ...I O N I Z A T I O N S O L U T I O N S Point of Use Ionizing Blower Model 6432e User s Manual...
Страница 6: ...19 6432 M 01 Rev 4 3 Figure 2 Back of Model 6432e Blower...
Страница 12: ...19 6432 M 01 Rev 4 9 Figure 3 Mounting Stand Knobs Screws and 8 pin Terminal Block...
Страница 15: ...19 6432 M 01 Rev 4 12 Figure 6 In tool Bracket Mounting Hole Locations on Underside of Bracket...
Страница 28: ...19 6432 M 01 Rev 4 25 4 Specifications 4 1 Specifications 4 2 Dimensional Drawings...
Страница 31: ...19 6432 M 01 Rev 4 28 4 2 Dimensional Drawings Blower with Benchtop Stand...
Страница 32: ...19 6432 M 01 Rev 4 29 Blower with In tool Stand...
Страница 33: ...19 6432 M 01 Rev 4 30...
Страница 35: ...19 6432 M 01 Rev 4 32...
Страница 36: ...19 6432 M 01 Rev 4 33 Notes...
Страница 37: ...19 6432 M 01 Rev 4 34 Notes...