Simco-Ion 6432e Скачать руководство пользователя страница 1

IONIZATION SOLUTIONS

Point of Use

Ionizing Blower

Model 6432e

User’s Manual

Содержание 6432e

Страница 1: ...I O N I Z A T I O N S O L U T I O N S Point of Use Ionizing Blower Model 6432e User s Manual...

Страница 2: ...es Simco Ion improves its customers business results by providing a total solution to their electrostatic discharge and electromagnetic interference challenges Simco Ion Technology Group is a division...

Страница 3: ...7 2 1 Box Contents 8 2 2 Mounting Stand Installation and Placement 10 2 3 Mounting Stand Knob Replacement 13 2 4 Blower Placement 14 2 5 Power Connections 15 2 6 FMS Connection 18 2 7 Turning on the...

Страница 4: ...19 6432 M 01 Rev 4 1 1 Description 1 1 Point of Use Ionizing Blower Model 6432e 1 2 IsoStat Technology 1 3 Performance 1 4 Power Requirements...

Страница 5: ...ectrostatically shielded to eliminate field induced charging Steady state DC ion emission provides fast discharge with low airflow The Model 6432e features a red alarm indicator LED on the front of th...

Страница 6: ...19 6432 M 01 Rev 4 3 Figure 2 Back of Model 6432e Blower...

Страница 7: ...electrostatically shielded to eliminate field induced charging Steady state DC ion emission provides fast discharge with low airflow Ionizers incorporating IsoStat technology never need calibration a...

Страница 8: ...center of the Blower Ionization balance is better than 20V at 1 ft 30 48 cm Table 1 Distance Discharge Time when Powered with 24 VAC Testing was performed with a charged plate monitor in accordance wi...

Страница 9: ...ide the Blower with appropriate 24 VAC power Universal power supply part number 14 1322 for use with 100 240 VAC systems provides 24 VDC output Caution The use of improper input voltage may result in...

Страница 10: ...7 2 Setup Operation 2 1 Box Contents 2 2 Mounting Stand Installation and Placement 2 3 Mounting Stand Knob Replacement 2 4 Blower Placement 2 5 Power Connections 2 6 FMS Connection 2 7 Turning on the...

Страница 11: ...may be included if they have been ordered A benchtop or in tool mounting stand One of the following three power supplies 120 VAC transformer 14 1320 01 230 VAC transformer 14 1330 AC DC universal powe...

Страница 12: ...19 6432 M 01 Rev 4 9 Figure 3 Mounting Stand Knobs Screws and 8 pin Terminal Block...

Страница 13: ...and Figure 4 Benchtop Stand 1 Fasten the Blower to the mounting stand using the molded knobs supplied with the chassis 2 To adjust the stand loosen the side knobs on the Blower and adjust the Blower t...

Страница 14: ...le 3 Re tighten the knobs to secure the Blower in place 4 Aim the Blower so that its airflow travels directly to your target Figure 5 In tool Stand Caution To ensure proper Blower stability the in too...

Страница 15: ...19 6432 M 01 Rev 4 12 Figure 6 In tool Bracket Mounting Hole Locations on Underside of Bracket...

Страница 16: ...ow for an improved grip on the mounting stand as they can be tightened down using a standard Phillips screwdriver To install the screws 1 One side at a time unscrew and remove the knobs from the sides...

Страница 17: ...use this Blower in an explosive environment Poorly maintained ionizers could produce minuscule electric arcs at the emitter points This may cause detonation in an explosive environment Achtung Verwen...

Страница 18: ...pply Connection InsertthepowercablefromthetransformerorACadapterintothe Power In receptacle on the back of the Blower See the Performance and Power Requirements sections for additional information AC...

Страница 19: ...the Blower from your process equipment The terminals are designed to accept wiring between 22 AWG and 16 AWG When wiring the Blower directly to a 24 VDC source observe the maximum voltage and power re...

Страница 20: ...a result of improper wiring connections or failure to heed maximum voltage limits will not be covered by the warranty Achtung Sch den am Produkt infolge unsachgem er Verdrahtung oder wegen unterlasse...

Страница 21: ...connects the Blower to the FMS using pins 1 5 Figure 11 FMS and 24 VDC Pins Table 2 FMS Output Status 24 VDC process equipment power 8 24 VDC return Ground 7 24V 6 Do not use 4 20 mA current loop 5 C...

Страница 22: ...e green Power LED will light Once the Blower is powered on its position may be readjusted to achieve optimum discharge time within the air pattern of the Blower To adjust the position of the Blower lo...

Страница 23: ...he Blower s alarm is not a maintenance alert In most cases service will be required Before contacting Simco Ion for service make sure that the Blower is receiving proper input voltage per specificatio...

Страница 24: ...19 6432 M 01 Rev 4 21 3 Maintenance 3 1 Maintenance Requirements 3 2 Cleaning the Chassis 3 2 Cleaning the Chassis 3 3 Cleaning the Emitter Points...

Страница 25: ...er points is the only routine maintenance required No readjustment of the ionizer is required after cleaning The Blower can be easily removed from the universal bracket by unscrewing the side knobs Re...

Страница 26: ...19 6432 M 01 Rev 4 23 3 2 Cleaning the Chassis Moisten a cloth with the IPA solution Wipe off any dirt that may have accumulated on the unit...

Страница 27: ...point to the center of the fan and are on the same horizontal plane The Blower uses internally shielded emitter points that will not normally require replacement during the service life of this produc...

Страница 28: ...19 6432 M 01 Rev 4 25 4 Specifications 4 1 Specifications 4 2 Dimensional Drawings...

Страница 29: ...ace Controls On off rocker switch Operating Env Temperature 10 35 C 50 95 F humidity 30 60 RH non condensing Dimensions 5 3H x 5 0W x 2 3D in 13 3 x 12 7 x 5 7 cm without stand Weight 16 oz 467g witho...

Страница 30: ...ompliant Mounting Stands Optional Material Finish Aluminum epoxy polyester powder coat both In tool and Benchtop gimbaled bracket stands Depth In tool 45 mm benchtop 108 mm Mounting Holes In tool 2 ho...

Страница 31: ...19 6432 M 01 Rev 4 28 4 2 Dimensional Drawings Blower with Benchtop Stand...

Страница 32: ...19 6432 M 01 Rev 4 29 Blower with In tool Stand...

Страница 33: ...19 6432 M 01 Rev 4 30...

Страница 34: ...valuating repairing or replacing any unit returned to Simco Ion that has not been subjected to misuse neglect lack of routine maintenance repair alteration or accident In no event shall Simco Ion be l...

Страница 35: ...19 6432 M 01 Rev 4 32...

Страница 36: ...19 6432 M 01 Rev 4 33 Notes...

Страница 37: ...19 6432 M 01 Rev 4 34 Notes...

Страница 38: ...Ste 100 Alameda CA USA 94502 Tel 510 217 0600 Fax 510 217 0484 Toll free 800 367 2452 Sales services 510 217 0460 Tech support 510 217 0470 ioninfo simco ion com salesservices simco ion com techsuppor...

Отзывы: