© simatec ag
Induction Heater IH 070/090
27
English
3 Installation of mains plug
Due to the many types of mains plugs, no mains plug is supplied with the
IH 070/090. A qualified electrician must install a suitable mains plug. The
correct supply voltage is shown in section 2.2.
The wires should be connected as follows:
IH 070
Colour of IH 070 wire
Mains supply terminal
yellow/green
green
Protection earth (PE)
brown
black
Phase 1 (L1)
blue
white
Neutral (N)
Connect the IH 090 to only two of the three phases. Verify that the correct
circuit breaker is installed. See section 2.2 for circuit breaker specifications.
IH 090
Colour of IH 090 wire
Mains supply terminal
yellow/green
Protection earth (PE)
brown
Phase 1 (L1)
blue
Phase 2 (L2)