RS232 Status Response
The returned data format (in response to a status request) takes the following format:
Message header = $*2 as per section 7.3 above (* = RS232 address).
Message data = VE?RE?CS?CL?SD?SL?SS?SA?SR?SP? (where ? represents a numeric value).
Note that the mnemonics are the same as for the received RS232 commands. Message contents are defined in the
following Table:
Mnemonic Meaning
Data
VE
Currently selected view channel (all MUXes)
1 - 7 = Channel Number
RE
Currently selected record channel (all MUXes)
1 - 7 = Channel Number
CS
Compander Status
0 = Off
1 = On
CL
Compander Level
1 = 10:1 (Compress)
2 = 2:1
3 = 1.3:1
4 = 1:1
5 = 1:1.3
6 = 1:1.7
7 = 1:2 (Expand)
SD
Dimmer Status
1 - 4 (1 = Min Level)
SL
Currently selected channel for record loop protection
0 = Off
1 - 7 = Channel Number
SA
Auto Select mode status
0 = Off
1 = On
SR
Record follows play (in Auto Select mode)
0 = Off
1 = Enabled
SP
Front panel lock-out status
0 = Front panel enabled
1 = Front panel disabled
IR commands take precedence over front panel key presses. Thus, if an IR command is received at the same time as one
of the front panel buttons is pressed, the IR command will be executed and the button press ignored. However, RS232
commands take precedence over both IR and front panel commands, so if an RS232 command is received at the same
time as an IR command, the IR command will be ignored.
Example:
Unit address: 0
To turn standby mode off: @0SS0
To turn dimmer status to min: @0SD1