![SilverStone SFX Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/silverstone/sfx-series/sfx-series_manual_1274178005.webp)
4
LOAD
+3.3V
+5V
+12V
-12V
+5Vsb
Condition_1
X
X
X
X
2.5A
Condition_2
0A
0A
0.1A
0A
0A
Condition_3
0A
0A
1A
0.3A
0.1A
Condition_4
0A
0A
20A
0.1A
0.1A
Condition_5
1A
12.8A
1A
0.1A
0.1A
Condition_6
12.8A
1A
1A
0.1A
0.1A
Condition_7
20A
10.8A
13.65A
0.3A
2.5A
Condition_8
6.06A
20A
13.65A
0.3A
2.5A
Condition_9
0A
0A
25A
0.1A
0.3A
LOAD
+3.3V
+5V
+12V
-12V
+5Vsb
Condition_1
X
X
X
X
2.5A
Condition_2
0A
0A
0.1A
0A
0A
Condition_3
0A
0A
1A
0.3A
0.1A
Condition_4
0A
0A
30A
0.1A
0.1A
Condition_5
1A
12.8A
1A
0.1A
0.1A
Condition_6
12.8A
1A
1A
0.1A
0.1A
Condition_7
20A
10.8A
26.16A
0.3A
2.5A
Condition_8
6.06A
20A
26.16A
0.3A
2.5A
Condition_9
0A
0A
37.5A
0.1A
0.5A
Voltage Source
Over Voltage Protection Point
+3.3V
3.76V-4.8V
+5V
5.75V-7.0V
+12V
13.5V-16.5V
4.2. LOAD CAPACITY SPECIFICATIONS
4.3. OVER VOLTAGE PROTECTION
SX300-B
SX450-B
The cross regulation defined as follows, the voltage regulation limits DC include DC Output ripple & noise.
Содержание SFX Series