background image

 

1.2 Safety Notes 

IMPORTANT

.........

 

 

This product must be installed by a qualified professional. 

 

In order to maintain this condition and to ensure a safe operation, it is absolutely necessary 
for the user to follow the safety instructions and warning notes 

 

The  manufacturer  will  not  accept  liability  for  any  resulting  damages  caused  by  the 
non-observance of this manual or any unauthorized modification to the device. 

CAUTION!

....

....

 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Do not touch the power cables if your hands are wet. 

 

The earth wire must always be connected to the ground. Therefore it is essential to connect 
the yellow/green conductor to earth. 

 

Make  sure  that  the  power-cord  is  never  crimped  or  damaged  by  sharp  edges.  Check  the 
device and the power-cord from time to time. The electric connection, repairs and servicing 
must be carried out by a qualified employee. 

 

Always disconnect power input cable to completely remove power from unit when not in use 
or before cleaning or servicing the fixture. 

 

Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life. 

 

Do not touch the device’s housing bare hands during its operation (housing becomes hot)! 
The surface of the product’s casing can reach up to 70° C (158° F) during operation. Avoid 
contact by persons and materials. Do not install the product in a location where there is a risk 
of accidental contact. Allow the product to cool for at least 10 minutes before handling. 

 

For replacement use lamps and fuses of same type and rating only.   

 

Please protect the fixture and avoid destroy during transport and installation. If there is any 
damage to the coating, the shell may be corroded. 

 

When hanging lamps and lanterns, it is necessary to verify that facilities and hooks can bear 
at least 10 times the weight of lamps and lanterns. 

 

Fix the safety rope at the correct holes only. Only operate the fixture after having checked 
that the housing is firmly closed and all screws are tightly fastened. 

 

The  maximum  ambient  temperature  45°C  must  never  be  exceeded.  Do  not  operate  the 
product if the ambient temperature (Ta) exceeds 45° C (115° F).   

E

lectrical 

..

..

W

arning

..

 

 

The light source contained in this luminaire shall only be replaced by the manufacturer or his 
service agent or a similar qualified person 

 
 
 

Содержание FREZNO 250 HEX

Страница 1: ...MODEL SS826XH FREZNO 250 HEX USER MANUAL FREZNO 250 HEX SS826...

Страница 2: ...PRODUCT 1 1 TECHNICAL SPECIFICATIONS Type SS826XH LED colors RGBALC 250W LED Power 250W Voltage Range AC100 240V 50 60Hz Protection IP20 Operation Temperature 0 45 Dimensions 375X254X393mm Weight 8 8...

Страница 3: ...fixture on and off in short intervals as this would reduce the lamp s life Do not touch the device s housing bare hands during its operation housing becomes hot The surface of the product s casing ca...

Страница 4: ...ure with a safety cable through the rear safety eye as shown Ensure that the structure truss to which you are attaching the fixture is secure Hanging layout 2 2 POWER CONNECTIONS SS826XH POWER Linking...

Страница 5: ...2 data link is required in order to control the fixture via DMX The fixture has 3 5 pin XLR connectors for DMX data input and output Each unit has 13 DMX channels so the DMX Addresses should increase...

Страница 6: ...YAN 0 255 STROBE 0 25 ADDRESS 001 512 default001 Set the DMX ADDRESS RUN MODE DMX default DMX Using the DMX 512 controller to control SLAVE Master Slave operation SLAVE PERSONALITY BASIC Use the menu...

Страница 7: ...utomatic rotation of fan DISP KEY ON default Locks display passcode is UP DOWN UP DOWN ENTER OFF DISP TIME ON Display backlight always on 10s Turns off display backlight after 10s 30s 2min of inactivi...

Страница 8: ...0 2700K 55 3000K 70 3200K 85 4000K 100 4500K 115 5000K 130 5600K 145 6000K 160 6500K 175 7000K 190 8000K 205 10000K 255 10000K CH 6 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOD TO FAST 0 25Hz 100 109...

Страница 9: ...ER DIMMER FINE CH 2 CH 2 CH 3 0 255 RED CH 4 0 255 RED FINE CH 3 CH 3 CH 5 0 255 GREEN CH 6 0 255 GREEN FINE CH 4 CH 4 CH 7 0 255 BLUE CH 8 0 255 BLUE FINE CH 5 CH 5 CH 9 0 255 AMBER CH 10 0 255 AMBER...

Страница 10: ...TO 9 131 140 AUTO 10 141 150 PROGRAM 1 151 160 PROGRAM 2 161 255 NO FUNCTION CH 11 CH 18 0 255 AUTO SPEED ADJUSTMENT CH 8 CH 12 CH 19 STROBE 0 9 NO FUNCTION 10 99 STROBE FROM SLOD TO FAST 0 25Hz 100 1...

Страница 11: ...unction CH 1 0 255 DIMMER CH 2 0 255 CYAN CH 3 0 255 MAGENT CH 4 0 255 YELLOW CH 5 PRESET COLOR 0 10 NO FUNCTION 11 255 PRESET COLOR See Annex I for details CH 6 CCT 0 9 NO FUNCTION 10 1800K 25 2200K...

Страница 12: ...NO FUNCTION 10 99 STROBE FROM SLOD TO FAST 0 25Hz 100 109 NO FUNCTION 110 179 LIGHTNING STROBE 180 189 NO FUNCTION 190 255 RANDOM STROBE CH 10 CONTROL EXECUTE AFTER 3 SECONDS 000 010 NO FUNCTION 011...

Страница 13: ...6 COLOR 23 121 125 R94 Kelly Green 0 185 0 459 COLOR 24 126 130 L327 Forest Green 0 162 0 496 COLOR 25 131 135 L191 Cosmetic Aqua Blue 0 3 0 318 COLOR 26 136 140 L728 Steel Green 0 256 0 302 COLOR 27...

Отзывы: