background image

 

 

INSTALLATION

 

The stainless steel exterior of the cabinet has been protected by a plastic covering during manufacturing and shipping.  This covering can 
be readily stripped before installation.  After removing this covering, wash the interior and exterior surfaces using a warm, mild soapy 
water solution and a sponge or cloth, rinse with clean water and dry. 
 

Casters

 

Models without a base come with Casters.  To install them, tilt the unit and thread the Casters into the four Rivnuts in the bottom of the 
cabinet.  Make sure that they are installed tightly to prevent future thread wear.  Return the unit to the upright position.  

**Allow at least 

two hours of off time before connecting to a power source.

 

 

Cutting Board

 

The Cutting Board is mounted on knobs installed on the front top surface of the cabinet.   
 

Shelves

 

Inside the unit you will find Shelves and a plastic bag containing Shelf Supports.  The Shelf Supports with the “tang” go on  the rear 
Pilasters.  This shelf system allows for easy adjustment to suit your needs. 
 

Door Adjustment and Swing

 

Should the Door ever require straightening, loosen the Screws on the Hinges, square the Door with the cabinet and retighten the Screws. 
 
The mounting of the Door is easily reversible on single door units should space or convenience require that you do so.  Simply remove 
the Screws holding the Hinges, rotate the Door 180 degrees and relocate the Hinges on the side opposite their original location. 
 

Location

 

When locating your new refrigerator, convenience and accessibility are important considerations, but the following installation guidelines 
must be followed; 
 
*Always avoid placing the refrigerator adjacent to an oven, heating element or hot air source that would affect the operation of the unit. 
 
*For proper ventilation the bottom front of the unit must not be obstructed.  The unit must be on legs or casters to raise it off the floor.  
The unit can be installed tight on the sides and must have at least 4” of clearance in back.    
 
*The unit must be level or tilted backwards slightly. 
 

Climate Class Rating 

Your Silver King Prep Table has a climate class 4 rating.  It is designed for use in areas not exceeding 30°C (86°F). 
 
 

 
 
 
 
 
 
 
 

Содержание SKRN36-ESUS1

Страница 1: ...Without Notice Marmon Foodservice Technologies 355 Kehoe Blvd Carol Stream IL 60188 Contact 800 328 3329 Silverking com Technical Manual and Replacement Parts List Commercial Refrigerator MODEL SKRN36 ESUS1 FORM NO 45221 SK REV B 7 2022 ...

Страница 2: ...djustments are required for normal operation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This refrigeration unit is not intended to be used at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the ma...

Страница 3: ...efrost refrigerator freezer Do not puncture refrigeration tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safety precautions must be followed Caution Risk of fire or explosion To be repaired only by trained service personnel Use only Silver King approved replacement parts Flammable refrigerant use...

Страница 4: ... for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odor WARNING Keep any required ventilation openings clear of obstruction Notice that servicing shall be performed only as recommended by manufacturer CAUTION Always be sure to keep area around the unit clean and free of clutter Failure to keep this...

Страница 5: ...or easy adjustment to suit your needs Door Adjustment and Swing Should the Door ever require straightening loosen the Screws on the Hinges square the Door with the cabinet and retighten the Screws The mounting of the Door is easily reversible on single door units should space or convenience require that you do so Simply remove the Screws holding the Hinges rotate the Door 180 degrees and relocate ...

Страница 6: ...ally toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of Fire Extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry che...

Страница 7: ...rking Discharge capacitors in a way that won t cause any spark using a Supco CapDis tool That no live electrical components and wiring are exposed while charging recovering or purging the system that there is continuity of earth bonding Repairs to Sealed Components During repairs to sealed components all electrical supplies shall be disconnected from equipment being worked upon prior to any remova...

Страница 8: ...l be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak Removal and Evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However for flammable refr...

Страница 9: ...ept in an appropriate position according to the instructions WARNING Ensure that the REFRIGERATING SYSTEM is earthed prior to charging the system with refrigerant WARNING Label the system when charging is complete if not already WARNING Extreme care shall be taken not to overfill the REFRIGERATING SYSTEM Prior to recharging the system it shall be pressure tested with the appropriate purging gas Th...

Страница 10: ...n again Allow the unit a minimum of one hour to respond to a control setting adjustment Defrost Your Silver King refrigerator is an automatic defrost unit and no additional plumbing is required Automatic defrosting is accomplished when frost buildup on the Evaporator Coil is cleared during Compressor off cycles Defrost water is collected in a pan located in the compressor compartment where it is e...

Страница 11: ...11 ...

Страница 12: ...RESSOR MOUNT 98106 14 DRIER 22677 SK 15 THERMOMETER 22409 SK 16 SHELF WIRE 33732 SK 17 SHELF SUPPORT WITH TANG 99531 18 SHELF SUPPORT 99530 19 PILASTER 20 IN 24600 SK 20 TROUGH PANS 46011 SK 21 POWER CORD 115V 32199 SK 22 EVAPORATOR FAN MOTOR 115V 37736 23 EVAPORATOR COIL 38337 24 CAPILLARY TUBE 99283 25 TEMPERATURE PROBE 46128 26 REAR SERVICE PANEL 45547 SK 27 KNOB THREADED 24305 28 CUTTING BOARD...

Страница 13: ...13 ...

Страница 14: ...ompare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and temperature are not similar or the resistance s value is not on Table 1 then the thermistor is not working properly and needs to be replaced If the resistance reads over limit then the thermistor is n...

Страница 15: ...replacement components such as shelving trays gaskets etc Warranty excludes interior liner or exterior shell Condensing coils must be cleaned at regular intervals Failure to do so can cause compressor malfunction and will void warranty Although cleaning requirements vary in accordance with operation of various products Silver King advocates a minimum monthly cleaning The Equipment warranty does no...

Страница 16: ... OEM parts will be issued at the OEM cost Replacement parts sold separately are warranted for 90 days from date of purchase Special installation applications including remote locations are limited in coverage by this warranty Any installation that requires extra work and or travel is the sole responsibility of the equipment purchaser ADDITIONAL WARRANTY GUIDELINES A factory issued Service Authoriz...

Страница 17: ...arge Any and all environmental attributes including environmental offset credit rights with respect to Silver King refrigeration units manufactured after September 1 2015 shall remain the property of Silver King and are not transferred IN NO EVENT SHALL SILVER KING BE LIABLE FOR CONSEQUENTIAL SPECIAL OR PUNITIVE DAMAGES THE REMEDIES OF PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE TOTAL LIABILI...