Silver King SKFCB84H-EDUS2 Скачать руководство пользователя страница 17

 

10 

PRODUCT ORDERING INFORMATION  

Call us toll-free at 1-800-328-3329 or 1-763-923-2441. Fax us at 1-763-553-1209. Visit 

www.silverking.com

 for 

stocking distributor, equipment specs, and current price list for your area.  

SERVICE / PARTS ORDERING INFORMATION  

Call us toll free at 1-800-328-3329. Select prompt 1 for Equipment Service and Tech Support or prompt 2 for 
Parts. 

TERMS AND CONDITIONS  

WARRANTY period may vary from customer to customer and is contract specific. All prices reflect payment in 
U.S. Dollars. Prices do not include any freight, duty, or taxes. Pricing subject to change without notice. No returns 
are accepted without prior written approval from the factory. An RMA (Returned Merchandise Authorization) 
form must be completed and then approved by Silver King. Please contact Silver King for details. Restocking fee 
will  apply.  All  electrical  equipment  is  single  phase.  Prices,  designs,  and  specifications  are  subject  to  change 
without notice. Payments via credit card are subject to a 3.5% surcharge.         

Any and all environmental attributes, including environmental offset credit rights, with respect to Silver King 
refrigeration units manufactured after September 1, 2015, shall remain the property of Silver King and are not 
transferred. 

IN  NO  EVENT  SHALL  SILVER  KING  BE  LIABLE  FOR  CONSEQUENTIAL,  SPECIAL  OR  PUNITIVE  DAMAGES.  THE 
REMEDIES  OF  PURCHASER  SET  FORTH  HEREIN  ARE  EXCLUSIVE  AND  THE  TOTAL  LIABILITY  OF  SILVER  KING, 
WHETHER  BASED  ON  CONTRACT,  WARRANTY,  NEGLIGENCE,  INDEMNIFICATION,  STRICT  LIABILITY,  TORT,  OR 
OTHERWISE, SHALL NOT EXCEED THE PURCHASE PRICE OF THE COMPONENT UPON WHICH LIABILITY IS BASED. 
SILVER  KING  SHALL  HAVE  NO  OBLIGATION  OR  LIABILITY  FOR  CONSEQUENTIAL  OR  SPECIAL  DAMAGES, 
INCLUDING BUT NOT LIMITED TO INDIRECT, PUNITIVE DAMAGES, LOSS OF USE, LOSS OF PRODUCT, DOWNTIME 
OR LOST PROFITS, ARISING OUT OR RELATED TO OR CONNECTED IN ANY WAY WITH THE PRODUCT OR ITS USE. 

© Silver King prices subject to change without notice 

Note:  Additional  Terms  and  Conditions  of  sale  may  apply.  Notice:  Specifications  subject  to  change  without 
notice. Contact factory for specific model agency approval. 

 

 

 
 
 

Marmon Foodservice Technologies  
355 Kehoe Blvd, Carol Stream, IL 60188  
1-800-328-3329, marmonfoodservice.com 

 

 

 

 

Содержание SKFCB84H-EDUS2

Страница 1: ...nt Parts List Freezer Chef Base MODEL SKFCB84H EDUS2 Specifications Subject to Change Without Notice FORM NO 46964 REV B 07 2022 Marmon Foodservice Technologies 355 Kehoe Blvd Carol Stream IL 60188 Contact 800 328 3329 Silverking com ...

Страница 2: ...red for normal operation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This refrigeration unit is not intended to be used at altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity ...

Страница 3: ...efrost refrigerator freezer Do not puncture refrigeration tubing Caution Risk of fire or explosion Flammable refrigerant used Consult repair manual owner s guide before attempting to service this product All safety precautions must be followed Caution Risk of fire or explosion To be repaired only by trained service personnel Use only Silver King approved replacement parts Flammable refrigerant use...

Страница 4: ... for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odor WARNING Keep any required ventilation openings clear of obstruction Notice that servicing shall be performed only as recommended by manufacturer CAUTION Always be sure to keep area around the unit clean and free of clutter Failure to keep this...

Страница 5: ... unit Align a plate caster over the 4 hole pattern and install the hex screws provided tightly to mount the casters The casters with brakes should be installed at the front of the cabinet Return the unit to the upright position Allow at least 24 hours of off time before plugging the unit into a power source Drawers To remove the drawers for cleaning simply open them fully release gray tabs and lif...

Страница 6: ...ally toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of Fire Extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry che...

Страница 7: ...rking Discharge capacitors in a way that won t cause any spark using a Supco CapDis tool That no live electrical components and wiring are exposed while charging recovering or purging the system that there is continuity of earth bonding Repairs to Sealed Components During repairs to sealed components all electrical supplies shall be disconnected from equipment being worked upon prior to any remova...

Страница 8: ...l be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak Removal and Evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However for flammable refr...

Страница 9: ...ept in an appropriate position according to the instructions WARNING Ensure that the REFRIGERATING SYSTEM is earthed prior to charging the system with refrigerant WARNING Label the system when charging is complete if not already WARNING Extreme care shall be taken not to overfill the REFRIGERATING SYSTEM Prior to recharging the system it shall be pressure tested with the appropriate purging gas Th...

Страница 10: ...o a control setting adjustment Defrost Your Silver King unit defrosts naturally and no additional plumbing is required Defrosting is accomplished when frost buildup on the Evaporator Coil is cleared during Compressor off cycles Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the room air It is important that the unit be installed level to allow...

Страница 11: ...10 ...

Страница 12: ... POWER CORD 115V 32199 SK 14 EVAPORATOR COIL 46853 15 CAPILLARY TUBE 99445 16 FAN MOTOR 115V EVAPORATOR 37736 17 DRAIN PAN ASSEMBLY EVAPORATOR 37718 18 TEMPERATURE CONTROL ELECTRONIC 46891 19 DEFROST PROBE 46140 20 TEMPERATURE PROBE 46141 21 POWER SWITCH 39431 SK 22 FRONT COVER ASSEMBLY 38839 23 CONDENSER COIL 39267 24 FAN MOTOR 115V CONDENSER 37736 25 COMPRESSOR KIT 115 60 INCLUDES ELECTRICALS AN...

Страница 13: ...12 ...

Страница 14: ...ompare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and temperature are not similar or the resistance s value is not on Table 1 then the thermistor is not working properly and needs to be replaced If the resistance reads over limit then the thermistor is n...

Страница 15: ...replacement components such as shelving trays gaskets etc Warranty excludes interior liner or exterior shell Condensing coils must be cleaned at regular intervals Failure to do so can cause compressor malfunction and will void warranty Although cleaning requirements vary in accordance with operation of various products Silver King advocates a minimum monthly cleaning The Equipment warranty does no...

Страница 16: ... OEM parts will be issued at the OEM cost Replacement parts sold separately are warranted for 90 days from date of purchase Special installation applications including remote locations are limited in coverage by this warranty Any installation that requires extra work and or travel is the sole responsibility of the equipment purchaser ADDITIONAL WARRANTY GUIDELINES A factory issued Service Authoriz...

Страница 17: ...arge Any and all environmental attributes including environmental offset credit rights with respect to Silver King refrigeration units manufactured after September 1 2015 shall remain the property of Silver King and are not transferred IN NO EVENT SHALL SILVER KING BE LIABLE FOR CONSEQUENTIAL SPECIAL OR PUNITIVE DAMAGES THE REMEDIES OF PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE TOTAL LIABILI...