Electrical Connections
Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to
power. The specifications on the data plate supersede any future discussion.
The standard refrigerated display case is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle,
1 Phase properly grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes.
Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the warranty,
terminate the manufacturers responsibility and could result in serious injury.
The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not
plugged into an extension cord.
OPERATION
Initial Start Up
After satisfying the installation requirements, the display case is ready to start. The display case will start when the
power cord is connected to the required power source. If the compressor does not start when the unit is initially
plugged in, check to make sure that the Temperature Control is not in the “off” position. Allow the unit to run for two
hours before loading it with product. When loading the unit with product, take care not to block the air flow at the end
of the cabinet as this would affect the units performance.
Temperature Control
The Temperature Control is located on the Evaporator Housing in the cabinet liner and is factory set to maintain an
average cabinet temperature of approximately 40 Deg F. To obtain colder temperatures,P turn the Temperature
Control stem clockwise and vice versa with a flat blade screwdriver. Allow the unit a minimum of one hour to respond
to a control setting adjustment.
Lights
If the lights fail to startup, twist the bulbs to make certain that they are seated properly in the lamp holders. There is an
on/off switch for the lights on the right end of the light raceway.
Defrost
Your Silver King refrigerator is an automatic defrost unit and no additional plumbing is required. Automatic defrosting
is accomplished when frost buildup on the Evaporator Coil is cleared during Compressor “off” cycles. Defrost water is
collected in a pan located in the compressor compartment where it is evaporated into the room air. It is important that
the unit be installed level or tilted slightly backwards to allow proper drainage of the condensate water
MAINTENANCE
Preventative maintenance is minimal although these few steps are very important to continued operation and
maximizing the life of the appliance.
Cabinet Surfaces
The cabinet interior and exterior are stainless steel and aluminum. These surfaces should be cleaned periodically with
a solution of warm water and mild soap, rinsed and wiped dry with a soft cloth. Should a surface become stained, do
not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the grain of the metal
to avoid scratching the surface. Do not use caustic cleaners on the stainless steel.
Condenser
Periodically, accumulated dust must be removed from the Condenser. First, disconnect the unit from the power supply.
Remove the End Panel. Vacuum or brush the Condenser at the rear of the cabinet. This will need to be done
regularly to maintain the Compressor warranty!
Doors
The roller wheels on the Doors should be examined regularly to insure they spin freely. If the wheel bearings become
sticky they should be lubricated with a penetrating lubricant. Do not use a lubricant that is sticky and will buildup.
MODEL
SERIAL NO.
DATE INSTALLED