background image

 

Troubleshooting Guide

 

Problem 

Solution 

Pump does not operate 

 

Ensure battery wires are connected to battery properly 

 

Check the inline fuse and fuse holder in the power loom 

 

Ensure the lower loom clip connector is correctly attached to 
connector on the pump 

Pump wiring overheating 

 

This can happen when pump is operated at high pressures 
for long periods of time 

 

If power loom has been extended, larger gauge wire may be 
required 

Pump does not self-prime 

 

Check filter, nozzles and spray lines for blockage 

 

Check for air leak on suction side 

 

Diaphragm may have a hole 

 

Pump valves may be stuck or blocked, clean pump rinse 
clean water backwards through pump 

Pump is overheating 

 

Ambient temperature or pump pressure is too high, spray at 
lower pressure or when environment is cooler (see 
specifications for relationship between pump pressure, 
amperage and ambient temperature) 

Spray pattern is uneven 

 

Adjust angle and pressure to boom less nozzle 

 

Check for blockage in nozzle 

 

If nozzles are worn or damaged replace them 

 

Troubleshoot 

Содержание K02A

Страница 1: ...00L 300L K02A K03A K03A 19B with boom VICTORIA HEAD OFFICE Telephone 61 03 9215 2700 Fax 61 03 9215 2701 www silvan com au NEW ZEALAND Hamilton New Zealand Telephone 64 07 8496 033 Fax 64 07 8496070 w...

Страница 2: ...OUR SPRAYER DETAILS Record the details of your Sprayer here for future reference when discussing service with your Silvan dealer ordering service parts or making a warranty claim DATE OF DELIVERY ____...

Страница 3: ...f incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services Any product which has...

Страница 4: ...uipment when handling chemicals and operating the sprayer Ensure that all operators and associated personnel are familiar with the legal regulations and codes of practice that apply to the safe use st...

Страница 5: ...ionally moulded translucent polyethylene tank U V stabilized and impact resistant with calibrated fill mark moulded into the tank Contains sump with drainage and special tank wall section that clips i...

Страница 6: ...the tractor size and spraying application Final spraying height is regulated by use of the tractor linkage control SPRAY NOZZLE SPRAY NOZZLE SELECTION CHART FAN TIP Colour Number FILTER LIQUID Pressur...

Страница 7: ...attachment points Warning Do not exceed the vehicle manufacturer s specified safe load and carrying capacity CONNECTING TO 12 VOLT DC SUPPLY The Sprayer requires a 12 volt DC power source A power loom...

Страница 8: ...a suitable pressure and droplet size for your application 13 If the pump begins to cycle on off you may require a different nozzle that is rated to allow for higher flow rates at your selected droplet...

Страница 9: ...spray lines and damaging the sprayer Warning Dispose of unused chemical and water used for rinsing in a manner that will not endanger people animals or the environment in accordance with local regula...

Страница 10: ...he ground speed can then be calculated as follows Speed km hr 360 100 As the output to the boom cannot be regulated on standard units the application rate can only be varied by changing the operating...

Страница 11: ...may be required Pump does not self prime Check filter nozzles and spray lines for blockage Check for air leak on suction side Diaphragm may have a hole Pump valves may be stuck or blocked clean pump...

Отзывы: