MESH-CEFL
Ceiling Flush Mount Passive Infra Red
(PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-CEFL is compatible with any qualifi ed Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
11/10/19
INS372 MESH-CEFL (Issue 04)
77mm
85mm
60mm
Ceiling void at
least
78mm deep
Requires 73/75mm
diameter hole in false
or plasterboard ceiling
9mm
2mm
DIAGRAM 5
HALL EFFECT / FACTORY RESET:
This function allows a reset to be carried out in
order to restore the default factory settings.
A factory reset will change the state of
MESH-CEFL from ‘provisioned’ to
‘unprovisioned’, i.e. all network settings will
be lost. This functionality is required to allow
reprovisioning MESH-CEFL where control over
the device is not functioning correctly.
TO REPROVISION:
Place a small magnet on the site of the Reset
/ Hall effect sensor (see diagram 6 below). To
trigger the reset the magnet must be held in
position for 5 seconds.
DIMENSIONS
RESET ZONE (behind moulding).
Magnet to be placed over this area
for reprovisioning.
STATUS LED.
Flashes rapidly when unprovisioned.
Flashes slowly when provisioned.
DIAGRAM 6
STATUS LED BLINKING SEQUENCE:
MESH-CEFL Unprovisioned: 30ms ON
300ms OFF
MESH-CEFL Provisioned: 15ms ON
2000ms OFF
Factory Reset:
500ms ON
1000ms OFF
Factory Reset (initial burst): 100ms ON
1000ms OFF
MESH package received:
30ms ON
50ms OFF
Attention (from network):
500ms ON
500ms OFF