20MulCenNX2.doc
Page 2
Latest update: 24 Feb -03
•
Instrument front
•
Pin connector
Reset:
To reset the unit: Keep the
CLR -
button depressed during start, ON.
NOTE!
All settings will be reset to default values and all Waypoints will be erased
Technical specifications
Dimensions:
NX2 MULTI Center: 160 x 185 x 45mm
(6,3 x 7,3 x 1,8 inch).
Bracket: According to drawing in Operation Manual
Instrument cable:
6 m (19,5 ft).
Power supply:
12V DC (10-16V). The instruments are polarity protected.
Power
consumption at 12 V:
84 mA at 12 V = 1 W
with maximum lighting: 145 mA at 12 V=1,7 W
Temperature range:
Storage: -30° to +80°C (-22° to +176°F)
Operation: -10° to +70°C (14° to 158°F)
Weight:
700 gram (24,7 oz).
Enclosure:
Splash proof
CE Approval:
The products conform to the EMC requirements for
immunity and emission according to EN 50 081-1 and
EN55022
20.1 Dismantling and re-assembly
•
Unscrew the five screws in the back cover.
•
Remove the white 8 pin connector from the PCB.
•
Remove the 12 wire flat-cable connector from the Display board.
•
Unscrew the two screws and remove the metal shield.
•
Unscrew the five spacers which holds the main PCB.
•
The PCB is fixed by three lockers.
Unlock the single on the left side
and lift the PCB a bit at the same
side. The PCB now can be removed.
See illustration.
•
Unscrew the two spacers which
holds the light guide and the
display. The display is also
fixed with addessive tape.
Re-assembly
Содержание NX2
Страница 1: ...Latest update 17 Feb 03 SERVICE MANUAL Art No 20972 03 Edition No 1 ...
Страница 46: ...94MtuDiagNX2 doc Page 1 Latest update 7 Jan 03 9 4 Circuit Diagram NX2 WIND TRANSDUCER ...
Страница 54: ...104DIAGRNX2 DOCn 03 Latest update 11 Feb 03 TP 2 TP 5 TP 6 TP 7 TP 4 TP 3 TP 1 ...
Страница 55: ...1041diagr35nx2 doc Latest update 11 Feb 03 TP 1 TP 2 TP 6 TP 9 TP 4 TP 3 TP 7 TP 5 ...