japa
315+
User manual
Translation
27
315+ 2.0 - 2020
5.5 Annual maintenance (1,000 hrs)
The 1,000 hr maintenance is intended to be performed once or twice a year, after approx. every 100–
150 days of use. The aim is to go through the entire machine, replace filters and perform adjustments.
The 200 hr maintenance tasks are also performed at the same time (5.4). Check all hydraulic hoses for
leaks or damage, and replace damaged hoses immediately! In BE models equipped with the electric
starter accessory, the electrolyte level (acid) of the battery must be checked and water added if
necessary.
TRH models do not require the 1,000 hr maintenance since they utilise external hydraulics.
A. Detach safety rod and three 13 mm screws in
the cover and lift the cover open. Ensure that the
locking plate moves into the locking position.
B. Place a container under the oil tank to collect
the discharging oil. The oil tank contains 30 l of oil.
Remove the plug in the bottom of the hydraulic oil
tank, and allow the oil to flow into the container
below. Once the oil has been drained, reinstall the
bottom plug.
C. Detach the filter cover and remove the old filter
cartridge and casing. You can add oil (30 l) when
the cartridge is removed. Install the new filter and
replace the cover.
D. Remove bottom plug C and drain the gear.
Reinstall the plug and add 0.2 l of transmission oil.
ALWAYS DEACTIVATE THE MACHINE AND DISCONNECT THE POWER SOURCE WHEN CARRYING
OUT MAINTENANCE!
THE TRH MODEL DOES NOT FEATURE A HYDRAULIC OIL PUMP OR HYDRAULIC OIL TANK!
AFTER MAINTENANCE, ALWAYS REATTACH ALL THE GUARDS YOU HAVE REMOVED AND CHECK
THE OPERATION OF THE SAFETY DEVICES BEFORE BEGINNING OPERATION!
A
B
C
Содержание Japa 315+
Страница 39: ...japa315 User manual Translation 33 315 2 0 2020 8 3 Hydraulics diagram...
Страница 40: ......