Страница 2: ...stimulation for achieving a high oxytocin concentration in the blood of the dairy animal and as a consequence thereof a complete extraction of milk even from the alveols into the udder cistern a gentl...
Страница 3: ...pectations with respect to successive milking and wish you luck in your stable Multilactor Bio Milker and Pulsameter are registered trademarks Siliconform GmbH Co KG 2013 all rights reserved subject t...
Страница 4: ...Contents Siliconform GmbH Co KG 2013 all rights reserved subject to technical changes 11 12 2013...
Страница 5: ...ler Only those cleaning and disinfection agents as well as acids must be used which are tested by Siliconform and which have been approved as appropriate agents for the Multilactor cleaning Usage of a...
Страница 6: ...e gates are monitored by light sensors and are closed automatically The cleaning agent is selected at the R D unit as required This variant is appropriate for Tandem Fishbone and Carousel milking parl...
Страница 7: ...Any hints with respect to mode of operation are identified in this manual with the corresponding symbol Siliconform GmbH Co KG 2013 all rights reserved subject to technical changes 11 12 2013...
Страница 8: ...the milking cups and transfers the stimulating motion to the udder via the milk hoses The control unit is disposed on the front of the housing Siliconform GmbH Co KG 2013 all rights reserved subject...
Страница 9: ...013 all rights reserved subject to technical changes 11 12 2013 Purge unit connections PES red Base acid blue Water white Pulsameter 2 Valve terminal Pulsator valves Pulsator Electric connection Contr...
Страница 10: ...fter the disinfection the device pivots into the base position and is ready for milking In order to start the milking the automated option in the gate control software has to be activated by the click...
Страница 11: ...t axis The pivot arm together with the magazine tilts towards the animal The hoses are released the milk cups can be attached Note that the hoses hang freely downwards in a wide arc however without to...
Страница 12: ...lock screw positioned at the right hand side below the touch panel is to be turned until it is locked The teat cup does not need to be put on the floor of the milking parlour Do not forget to reset th...
Страница 13: ...t hand side milking box is blocked for automatic button turns red when box is blocked Tierkennung upon touching the animal number may be entered or corrected manu ally until detachment note Multilacto...
Страница 14: ...reduced to a type of oscillation that is con venient and gentle for the animal in order to achieve a milking of the cow that is as convenient as possible The vacuum value for milking should be adjuste...
Страница 15: ...milking cups are lowered into the purge unit and are purged with pure water so that residue free teat rubbers are available for the next milking process Caution peracetic acid is a highly corrosive li...
Страница 16: ...king cups are positioned in the purge receptacle At first the Bio Milker valves are cleaned The increased vacuum of 50 kPa is activated the pulsation is adjusted to a common mode pulsation The tubes o...
Страница 17: ...trol will not automatic ally be released If an animal is milked into the bucket the controller automatically enters this animal into the list of blocked animals deletion of such an animal is only poss...
Страница 18: ...ter the detachment of the milking cups the following milk data milking time milk flow curve amount averaged milk flow are transferred to the PCs and stored to gether with the animal s identification n...
Страница 19: ...eaking Check pulse hoses for damage water in hose weekly Visually check Bio Milker valves for contamination monthly Check whether components are freely movable Check spray nozzles possibly need to be...
Страница 20: ...rrectly performed Controller Pneumatic valves defective for example due to lack of air quality Pneumatic cylinders move tightly adjustments of the exhaust air throttles or damping adjustment not corre...
Страница 21: ...itch Disconnect knee switch and start with the start button Replace knee switch Pulsation does not work Main filter for fresh air is clocked Controller is defective Contamination in pulsator Replace f...
Страница 22: ...less or no water during purging Filter in the valve is clocked Valve is defective Clean filter Service Water splashes all the time Contamination in water valve Failure in wiring Call service Water in...
Страница 23: ...ent position is highlighted in white Purple button A opens the exit of the respective milking box Yellow button E opens the entry gate of the respective milking box links rechts Central entry gates a...
Страница 24: ...is milking box Tore Menu for manual gate control Status information in upper line left side milking box being populated Central blue display area Information about milking box containing a waiting cow...
Страница 25: ...1 Main purging number of steps 18 0 20 Z4 Tilt time down 1 10s 10 0 21 Z3 Tilt time up 1 10 20 0 22 Z15 Cup detachment waiting time 1 10s switch off delay 8 0 23 Min milk flow for main milking kg min...
Страница 26: ...imulation steps 5 0 40 Z21 Pre purge time 1 10s 100 0 41 Z30 Pre stimulation time 1 10s 500 0 42 Z22 Vacuum removal 1 10s 100 0 43 Number of water fillings 1 44 Z16 Water spray time 1 10s 15 45 Z17 Po...
Страница 27: ...Y2 Hose down Y3 Pivot inwardly Y4 Pivot autwardly Y5 Tilt magazine Y6 Stimulation Y7 Flood Pulsameter2 Y8 Y9 Dose PES Y10 Spray nozzles for water Y11 Flood container Y12 Spray hoses Y13 Switch off val...
Страница 28: ...purge apparatus The purge apparatus has to provide a floating contact for switching a 24V signal sent by Multilactor in order to start the valve purging and the main cleaning procedure Note the follo...
Страница 29: ...side Exit Entry Milking box1 Milking box2 Milking box3 Milking box4 Milking box5 Milking box6 Milking box7 Milking box8 Numbering in a hearing bone parlour is analogous Siliconform GmbH Co KG 2013 al...
Страница 30: ...included PC Operating system Windows7 Optionally an industrial PC is available with surcharge 1 7 7 Attachments Technical data Multilactor List of replacement parts drawings in exploded view Manual fo...