Innovative Solar Solutions | 2917 State Hwy 7, Bainbridge, N.Y. 13733 | Ph: 800.786.0329 | www.SiliconSolar.com
3. ASSEMBLING
1) Completely unroll the connecting cable on the stream pump.
2) Attach the hose onto the outlet of the hose connection. The hose connection is suitable for various hose
diameters (inside diameter 25,32 or 38 mm).
3) Mount the hose connection to the pump outlet by means of the enclosed gland nut. Via the ball joint, the angle of
the hose connection may be adjusted under water when necessary.
4) Completely immerse the stream pump into the water.
5) Connect the pump to the solar panel, and tighten the screw for protection.
6) Install the solar panel in garden lawn or soft ground by means of the spike
and adjust the angle to face the
solar modules toward the sun
.
7) The solar pump is now ready to operate.
3. CAUTIONS
1) Any altering of the product itself or changing of the components voids warranty.
2) Do not connect the pump to any AC voltage power directly; it’s ONLY for DC
voltage power.
3) Operate the pump in water only (never above 40
℃
), especially keep it away
from flammable liquids.
4) All the connectors are protected against reverse polarity as shown in the right
figure. Don’t insert the plug with reverse polarity by using unnecessary force.
5) The pump is dry run protected. The pump will automatically stop when there is
no enough water.
5. CLEANING AND MAINTENANCE
If the pump starts losing power or stops working after operating for a certain time, please clean up the sediment
inside the pump or the debris on the filter cribs.
The pump can be opened by unscrewing the four screws on the four corners of the filter housing bottom.
To clean the pump, disassemble the pump according to the above figure and then clean all parts with water.
Be careful, never drop down the ceramic axis while cleaning the impeller, it breaks easily.