10.5.16 EMU_DCDCMISCCTRL - DCDC Miscellaneous Control Register
Offset
Bit Position
0x04C
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reset
0x0
0x3
0x1
0x0
0x7
0x7
0
1
1
0
Access
R
W
R
W
R
W
R
W
R
W
R
W
R
W
R
W
R
W
R
W
Name
Bit
Name
Reset
Access Description
31:30
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
29:28
LPCMPBIASEM234H 0x0
RW
LP Mode Comparator Bias Selection for EM23 or EM4H
LP mode comparator bias selection. Reset with POR, Hard Pin Reset, or BOD Reset.
Value
Mode
Description
0
BIAS0
Maximum load current less than 75uA.
1
BIAS1
Maximum load current less than 500uA.
2
BIAS2
Maximum load current less than 2.5mA.
3
BIAS3
Maximum load current less than 10mA.
27
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
26:24
LNCLIMILIMSEL
0x3
RW
Current Limit Level Selection for Current Limiter in LN Mode
High-side current limiter’s current limit level selection in low noise mode. The recommended setting is calculated by LNCLI-
MILIMSEL=(I_MAX+40mA)*1.5/(5mA*(1))-1, where I_MAX is the maximum average current allowed to the load,
and 40mA represents the current ripple with some margin, and the factor of 1.5 accounts for detecting error and other varia-
tions. For strong (i.e., low internal impedance) battery, it is recommended to have I_MAX=200mA. I_MAX should never be
set higher than 200mA to avoid reliability issues. Reset with POR, Hard Pin Reset, or BOD reset.
23
Reserved
To ensure compatibility with future devices, always write bits to 0. More information in
22:20
LPCLIMILIMSEL
0x1
RW
Current Limit Level Selection for Current Limiter in LP Mode
Sets high-side current limit in low power mode, with maxixum current equal to 40 mA*(1+LPCLIMILIMSEL). Recommend
setting LPCLIMILIMSEL=1, corresponding to a maximum current of 80 mA for optimal efficiency and to support up to 10
mA loads when LPCMPBIASEM234H=0x3. Reset with POR, Hard Pin Reset, or BOD reset.
19:16
BYPLIMSEL
0x0
RW
Current Limit in Bypass Mode
Set current limit in bypass mode when BYPLIMEN equals one. The limit is from 20mA to 320mA, with 20mA/step. Reset
with POR, Hard Pin Reset, or BOD Reset.
15:12
NFETCNT
0x7
RW
NFET Switch Number Selection
Low Noise mode NFET power switch count number. The selected number of switches are 1. This may cause a
very momentary efficiency hit. Reset with POR, Hard Pin Reset, or BOD Reset.
Reference Manual
EMU - Energy Management Unit
silabs.com
| Building a more connected world.
Rev. 1.1 | 257