007-6442-002
Replacing a BaseIO Card in an SGI® UV™ 300H Server
1
...............................................................................................................................................................................
Replacing a BaseIO Card in an SGI
®
UV
™
300H Server
A video of this procedure is available.
After troubleshooting and verifying the symptoms of a BaseIO card failure, complete the following
procedure to prepare the system for BaseIO replacement, remove the faulty BaseIO card, install the
new card, and return the system to operational status.
BaseIO Card Failure Symptoms
The following symptoms may indicate BaseIO card failures:
•
eth0 is not available.
•
eth0 performance is degraded.
•
USB ports are not available.
•
Boot drives are not accessible.
•
System does not boot.
Safety Precautions
A fully-loaded chassis weighs approximately 125 pounds. Do not attempt to remove a chassis from
the rack by yourself.
You do not need to completely remove the chassis from the rack to replace a BaseIO card. Slide the
chassis out the front of the rack until the safety locks engage at the halfway point to keep the chassis
in place. Then, remove the front top cover to access parts for replacement.
Be sure to observe all ESD, electrical, and safety precautions when you perform the BaseIO card
replacement procedure. For more information, refer to the
SGI UV 300 System User Guide
, SGI
publication number 007-6351-00x.
Component
Part Number
CRU/FRU
Hot Swappable?
Access Position
BaseIO Card
030-2929-00x
CRU
No