LED Status Indicators
007-5832-002
73
LED Status Indicators
There are a number of LEDs on the front of the IRUs that can help you detect, identify and
potentially correct functional interruptions in the system. The following subsections describe
these LEDs and ways to use them to understand potential problem areas.
IRU Power Supply LEDs
Each power supply installed in an IRU has a bi-color status LED. The LED will either light green
or amber (yellow), or flash green or yellow to indicate the status of the individual supply. See
Table 7-2 for a complete list.
Table 7-2
Power Supply LED States
Power supply status
Green LED
Amber LED
No AC power to the supply
Off
Off
Power supply has failed
Off
On
Power supply problem warning
Off
Blinking
AC available to supply (standby)
but IRU is off
Blinking
Off
Power supply on (IRU on)
On
Off