168
007-4653-001
11: D-brick2
Loop Resiliency Circuit (LRC) Modules
The D-brick2 uses a Fibre Channel arbitrated loop (FC-AL) to interface with your Origin
3900 server. The FC-AL backplane incorporates two independent loops formed by port
bypass circuits within the LRC modules.
The enclosure services processor housed on the LRC modules manages the enclosure and
provides an interface to devices on the backplane, a PSU/cooling module, and an ops
panel to monitor internal functions. These processors operate in a master/slave
configuration to allow failover. See the
SGI Total Performance 9100 (2Gb TP9100) Storage
System User’s Guide
(P/N 007-4522-00x) for details.
Note:
The LRC module can address up to 96 disk drives; a maximum of six enclosures
can be cabled together.
The enclosure may be configured with either one or two LRC I/O modules (see
Figure 11-7). If only one module is installed, an I/O blank module must be installed in
the unused bay.
Figure 11-7
D-brick2 Loop Resiliency Circuit (LRC) Module
RS232
FC-AL
Loops
ESI fault LED
FC-AL signal present LED
FC-AL signal present LED
RS-232 port
FC-AL signal present LED
FC-AL signal present LED
Содержание Origin 3900
Страница 1: ...SGI Origin 3900 Server User s Guide 007 4653 001 ...
Страница 3: ...007 4653 001 iii Record of Revision Version Description 001 October 2003 Original Release ...
Страница 4: ......
Страница 12: ......
Страница 18: ......
Страница 62: ......
Страница 65: ...Product Description 007 4653 001 39 Figure 2 1 512 processor Origin 3900 Server ...
Страница 76: ......
Страница 104: ......
Страница 120: ......
Страница 172: ......
Страница 198: ......
Страница 208: ......
Страница 254: ......
Страница 274: ......
Страница 292: ......