“Cata” / “Ana” modes:
•
All jewelleries must be removed.
•
Place the contact electrode covered with wet gauze, under the shoulder, when working
around face area or upper body or under the thighs when working on lower body.
•
Apply a layer of
Sensibilis Lotion / Sensiblis Gel
(post-depilation soothing gel for
“Cata”
mode and pre-depilation lotion for
“Ana”
mode).
•
Use the roller electrode over the treated area for 3 minutes.
(Never use metallic roller on
bare skin).
•
Remove gel and rinse the skin.
•
To prevent electrode deterioration, remove gel residues from roller electrode.
•
Use bactericidal wipes to disinfect roller.
Recommended intensity settings for “Cata” mode:
•
For Face:
0.35 mA to 1.00 mA
•
For Body:
1.00 mA to 2.00 mA
ü
Treatment should be comfortable and soothing.
ü
Client should feel very light tingling or cooling sensation.
ü
A tingling may also be felt under the contact electrode (make sure the electrode is
covered with wet gauze).
Recommended intensity settings for “Ana” mode:
•
For Face:
0.30 mA to 1.00 mA
•
For Body:
1.00 mA to 2.00 mA
ü
Note: This phase should
NEVER
be used after electrolysis treatments.
ü
Client should only feel slight tingling. Lower intensity if client is uncomfortable.
ü
Treatment should never cause any discomfort.
ü
A tingling may also be felt under the contact electrode (make sure the electrode is
covered with wet gauze).