COPYRIGHT SILENTRON
DF5051XC011204M
SILENTRON - ITALIA
4
MULTIFUNCTIONAL RADIO RECEIVER
RX 1 TOP is a radio-receiver powered at 12V CC that may receive by self-coding all codes arriving from transmitting
units beloging to SILENT TOP range. It may work in different ways: monostable , bistable or mixed, according to type of
transmitting unit used. The working mode chages automatically according to type of programming and transmitter
used.
RX 1 TOP may record up to 16 different transmitting units. 3 L.E.D. indications - red, yellow and green - for the different
functions.
A
USE AS A RADIO ALARM RECEIVER
RX 1 TOP programmed with alarm detectors only, such as:SENSOR and PIR, work as an alarm receiver with tamper
protection. The reception of a tamper alarm or intrusion alarm causes temporary opening of the relays A (tamper) and
B.(alarm). The tamper protection of the housing is ON when JP is open.
B
TO LINK YOUR SYSTEM TO A CENTRAL MONITORING UNIT (digital communicator)
(JP shunt open)
RX 1 TOP programmed with a SILENT control panel (5000 - 5001 - 5003) works as a repeater of the panel status. When
you programme the control panel you cannot program any other transmitting unit. L.E.D.s and relays operate as follows:
•
panel armed:
yellow LED lits up - the contact of relay A is open
•
panel disarmed:
the LED is off and the contact of relay A is closed.
•
panel in alarm:
red LED lits up - the contact of relay B is open for 3 mins - When panel is disarmed the alarm stops
(contact B closed)
C
USE AS A BISTABLE KEY TO YOUR PANEL
(JP shunt is closed)
Programmed with K-top remote controls only, the RX1 will switch on/off your panel (contact relay B) and it will confirm
the operation via the contact relay A that opens contact for one pulse when panel is switched OFF, or for three pulses
when panel is switched ON.
D
USE AS A MINI CONTROL PANEL
(JP shunt is closed)
In case of programming with both pocket remote controls and detectors, RX1 TOP may be armed and disarmed via K-
TOP remote controls, with confirmation via contact relay A (1 or 3 pulses) and yellow LED.
When
armed,
SENSOR and PIR detectors may cause alarms that will be shown on red LED and driven by a 3 mins. temporary
opening of relay B.
TECHNICAL FEATURES
POWER SUPPLY:
10-14V cc - 5mA max in stand by with relays off.
FREQUENCY
: to european standards
TYPE OF CODING
: by self-learning with functional adresses.
CONTACTS RANGE COVER
500mA at
14V cc
TAMPER:
tamper switch against opening of housing in serial with relay A. It may be ejected via JP shunt.
DIMENSIONS AND WEIGHT
: 65 x 45 x 20mm
-
white ABS
-
weight 50gr.
PROGRAMMING TRANSMITTING UNITS:
a) power RX1 with RESET button pressed (erase) - when RESET is let go
yellow L:E:D: will flash. b) program transmitters or control panel: yellow L.E.D. switches on for 2 secs to confirm it. c) at
the end press on RESET to go out of programming. If you program 16 transmitters or one control panel, exit from
programming is automatic.
TO ADD MORE TRANSMITTERS
: press on RESET - yellow L.E.D. flashes - program other transmitters then exit by
pressing on RESET.
S
PECIAL FUNCTIONS OF SENSOR TOP CONTACTS:
if they are programmed on RX1 TOP with dip-switch 3 in ON
position relay B contact stays open until the corresponding door protected by SESOR is open. This functions may be
used for general purposes.
HOW TO PROGRAMMING THE DIFFERENT DEVICES
REM.CONTR. K TOP
Pressing on both red and green keys during 2 seconds
CONTROL PANELS
Turn mechanic key on control panel from TEST to u or reverse or arming/disarming the panel
DETECTORS
Connect the battery inside.
REM.CONTR.K-TOP R
Pressing on both red and green keys during 8 seconds (led lighting - pause - lighting)