Typical Deployment Scenario
The below architecture outlines a typical deployment scenario
Notes:
Personnel Movement
The above deployment includes a forced chanell that the individuals have to walk through. This
ensures a compliant pose when walking towards the camera. It also provides time for the individuals
skin temperature to stabilize versus the internal temperature and reduce the impact brought about
by the outside environment.
Camera
Placement
The Camera / Guide Belt placement ensures personnel cannot get
‘too close’ to the cameras. Any
measurements away from the set range (typically 2m) will become less accurate. If they are
measured further away, the read temperature will be lower. If they are measured closer the read
temperature will be higher (potentially leading to false alarms).