The charger (600 W) is part of the battery pack, so all you need to charge the battery is a mains power point and the power cable. It uses convection cooling.
-
To connect
, first plug in the IEC connector (scooter or battery) and then plug it into the mains. It is important to fully charge the battery after it has
been partially used 3 or 4 times.
-
To disconnect
, first unplug it from the mains and then unplug the IEC connector. The charging process can be stopped at any time. Also, the control
system will stop charging the battery when it reaches 100%.
If the battery temperature is below
0ºC or over 45ºC
(due to improper use), it will not charge.
If it is connected
while it is at a low temperature, an internal heater will be switched on, so the battery will
not be connected until it reaches a temperature of 15ºC
(in the case of battery units with this element
activated)
. This heater works when plugged into the mains and allows the power to be transferred at the
right temperature. However, this has an impact on the charge time, which will take longer than if the
temperature conditions were within the normal range.
For cold regions and seasons, we recommend keeping the battery plugged into the mains so the heater can
warm the cells and keep them at the right temperature for the scooter to be used normally.
*To ensure the validity of your battery's warranty, you must charge it fully (to 100%) at least once a month
. If you know you will not be using it for a while, it
is important to leave the battery with enough charge so that it doesn’t reach critical levels. Batteries that fall below a ce
rtain level of voltage no longer work on
their own, meaning they cannot be charged and must be taken to an Official Service Centre.
IMPORTANT!
Charge the battery fully once every
30 days to ensure the validity of the