10.13 ALIGNING/CALIBRATING THE CLAMP
The key-cutting machine comes from Silca with the clamp perfectly aligned. Alignment is necessary only if:
-
a jaw falls from the clamp and has to be replaced
-
caduta accidentale del morsetto
1) Make sure the motor ON switch is OFF.
2)
Fit and secure the 2 calibrating pins (provided) to the 2 spindles as if they were tools. N.B.: the flat part (with
greater diameter) must be visible (towards the clamp).
3) Turn on the key-cutting machine with the master switch (P).
4) Enable the key pad /calibration control board with key (K1).
5) Disable the tracer point spring (Ch. 8.4).
6) Place the clamp set on the right or left hand notch, according to the control to be performed.
Fig. 79
Fig. 80
10.13.1 CONTROL ALIGNMENT LEFT-HAND STATIONARY jAWS
1) Lower the vertical carriage with the lever (D (Fig. 80).
2) Align the 2 pins on the key surface (Ch.8.3).
3) When the pins are aligned, raise them slightly with the lever (D) so that they are not in contact with the key
surface.
4) Turn the lever (D) clockwise to lock the height of the vertical carriage.
5) Move the clamp carriage with the lever (C) and take the pins into contact with several points on the left-hand
jaw (also on the side of Stop 0). If the calibration board shows a green light the left-hand jaws are aligned.
6) If not, loosen the 2 screws (B3) and regulate the jaw (if necessary, loosen the 2 nuts (B4) and regulate the 2
grub screws B5) until the condition described above is achieved.
Fig. 81