Detector inputs: 

EGR-1 has 3 inputs, but 

only 2 inputs may be used at the same time: 

either S1 and S2 or T1 

and S2. T1 is exclusively for a temperature sensor (if needed). S1 and S2 are inputs for detectors. 

Possible combinations: 

 

Temperature sensor in T1 and detector in S2 

 

Detector in S1 and detector in S2 

 

Connect the detection loop of the detector to input terminals S1 (or S2) and GND. 
 
A resistor inside each detector tells EGR-1 about the type of the detector. The recognized values are 
the following: 

10K = PIR 
12K = Fire 
15K = Water 
18K = Magnet 
22K = Gas 
27K = other types 
33K = generic burglary 

 
Such a resistor is built into all detectors sold by Sikom. For other detectors, mount a suitable 
resistor in series with the detector, if the detector is of type NC (Normally Connected), and mount 
the resistor in parallel with the detector, if it is of type NO (Normally Open).

 

 

REGISTRATION WITH THE CENTRAL UNIT 

 
1.

 

Go to the setup, then the device registration screen. 

 

If needed, please refer to the registration procedure  
in the user manual of the central unit. 

 
2.

 

Press then the 

SW

 button of EGR-1 for at least 5 seconds. 

3.

 

On the screen of the central unit, enter the name to be given to the device.  

4.

 

The message “Registration OK” will then be shown on the display of the central unit, as well as 
the 2-digit registration number assigned to this EGR-1 module. 
Please write down this number for the end user, as it is required for remote control. 

 
 

IMPORTANT INFORMATION REGARDING FROST PROTECTION 

 
The thermostatic regulation offered by Sikom devices may be used to maintain a base “eco” 
temperature in your premises, but 

must not be taken as an infallible frost protection

.   

 
Indeed, any electronic equipment is vulnerable to power surges and other perturbations that may 
come from the electricity network, e.g. due to lightning. In such an event, if the electronics is 
damaged, it may no longer ensure the thermostatic regulation, and hence the frost protection.   
 
Therefore, if frost protection is a critical requirement (such as around water pipes), it is 
recommended to add a security mechanism. These are some alternatives:  

 

Use an additional heating system, with its own thermostat, to ensure frost protection in 
critical premises.  

 

Install a protection against power surges and other perturbations from the electricity 
network.  

 

Set up a bimetal thermostat in parallel with your Sikom unit. 

 

Sikom and its representatives will not assume liability for any damage due to frost!

 

Содержание EGR-1

Страница 1: ...e for any kind of detector fire flooding gas burglary motion detector or magnet contacts EGR 1 offers a thermostatic regulation function which is only available if a temperature sensor is connected to input T1 The user can then enter desired eco comfort temperatures into the system to obtain a programmable thermostat which can easily be toggled between eco and comfort temperatures OPERATION EGR 1 ...

Страница 2: ...s possible from any sources of electrical interferences Thermostatic regulation and temperature reading may otherwise be perturbed The temperature sensor should therefore not be used as a floor sensor for floor heating installations as this would require shielded twisted pair sensors and filters Similarly whereas it is possible to extend a temperature sensor it would also induce a loss of precisio...

Страница 3: ...1 for at least 5 seconds 3 On the screen of the central unit enter the name to be given to the device 4 The message Registration OK will then be shown on the display of the central unit as well as the 2 digit registration number assigned to this EGR 1 module Please write down this number for the end user as it is required for remote control IMPORTANT INFORMATION REGARDING FROST PROTECTION The ther...

Страница 4: ... circuits and appliances connected to the units install and use this product responsibly Costs related to re installing transporting and dismantling units recycling may be governed by special rules see the relevant chapter Damages caused by use outside of the operating conditions specified in the manual Malfunctions caused by transport damages Any unauthorized repair modification or disassembly Us...

Отзывы: