Package contents
1 pcs wireless multi thermostat with front cover
1 pcs 47KOhm floor temperature sensor 3 m cable (Microsafe)
Description
The thermostat can be controlled by Sikom ECO and COMFORT
sentral units. A floor sensor or internal room sensor can be used.
You can easily switch between a economy temperature (Eco) and a
normal temperature (Comfort). Temperatures are adjustable.
Important information
The thermostat does not offer galvanic isolation. All parts, including
the floor sensor must therefore be regarded as connected directly to
live wire.
Radio range
The radio range for remote control is up to 80 meters in line of sight.
Thick walls and floors of wood and concrete will decrease the
range. Effective range in a house is a approximately 20 meters.
Installation
Floor sensor must be placed inside a sealed pipe, right in the middle
between two heating cable segments, and as close to the surface
as possible.
Silver label shows how to connect 230VAC and load. Connect floor
sensor to the 2-pole connecting terminal. Place in wall box. Place
front cover on top. Connect cable between top and bottom and snap
top into the front cover.
Registration with a Sikom central unit
1. Activate the registration procedure on the Sikom central unit.
Read the user manual for your Sikom central unit to find the
correct procedure.
2. Within 1 minute, turn ECO Thermostat SI-4 ON by pushing on/
off button. If ECO Thermostat SI-4 is already turned ON, please
turn it OFF and ON again by pushing on/off button.
Successful registration indicates that radio range is ok.
To register additional thermostats, repeat procedure for each one.
Display and buttons
Eco Thermostat SI-4 shows set temperature in the display. The
display automatically dims after a while. Push a button for full
brightness.
Operation
The thermostat can be operated by using the control buttons:
•
Switching between Eco and Comfort temperature:
1. Push the up button to set Comfort temperature: Green led is
active.
2. Push the down button to set Eco temperature: Red led is active
•
Adjusting the set temperature manually:
Select Eco or Comfort mode.
1. Push the «P» button. The dots in the display will start flashing,
and the set temperature will be shown for the selected mode.
2. Use the up and down buttons to adjust the temperature setting.
3. Push the «P» button to store setting and exit menu.
Advanced setup
The thermostat has a menu for advanced settings:
1. Turn the thermostat off by pushing the «on/off» button.
2. Briefly push the «on/off» button simultaneously with the "arrow
up" button.
3. The thermostat will show «P1» ,- then the programmed value.
4. To navigate between the menus, push «P» button. «P0 to P9»
will be shown in the display. When reaching correct menu, wait,
and the setting will be shown. Adjust the setting with the up and
down buttons.
5. Push the «on/off» button to store settings and exit the advanced
menu.
Menu:
Explanation:
Min
Max
Std
P0
Check measured temperature -
-
-
P1
Floor sensor type
1
6
1
P2
Max floor temperature
25
30
27
P3
Temperature compensation -5
5
0
P4
Display brightness, dimmed 0
45
30
P5
Choose sensor
1
3
1
P6
Temp. regulation cycle time 5
50
10
P7
Not in use
P8, P9
Not in use, must be set to OF (OFF)
Menu P0 Check measured temperature
Check measured temperature from floor or room sensor.
Menu P1 Floor sensor type
6 different floor sensor types can be used.
1 = Microsafe (std) 2 = Microtemp
3 = Devi
4 = Elko
5 = Ebeco
6 = SI-2 thermostat
Menu P2 Max floor temperature
If the “Max floor", function is activated in menu P5, the temperature
limit can be adjusted here. Floor sensor required.
Menu P3 Temperature compensation
When using a floor sensor, there will be a deviation between the
measured temperature in the floor and the actual temperature in the
room. Compensate max + - 5 degrees Celsius with this function.
Compensation is also available when using room sensor or max
floor temperature. Compensation will then affect room sensor.
Menu P4 Display brightness
Adjust display brightness for dimmed display mode.
Menu P5 Choose sensor
1 = Floor sensor. Measures and regulates using floor sensor.
2 = Room sensor. Measures and regulates using room sensor.
3 = Max floor. Measures and regulates using room sensor, but limits
the temperature in the floor by limit set in Menu «P2».
Menu P6 Temperature regulation cycle time
Temperature regulation cycle time can be adjusted. Small rooms
may require shorter cycle time for regulating correctly.
Menu P7, P8 and P9
Not in use. NB: Menu P8 and P9 must be set to OF (OFF)
Error messages in display:
E0: No floor sensor. Check settings in menu P5. Sensor connected?
E1: Faulty radio. Contact dealer.
E2: Overheating inside the thermostat. Check load and connections
E3: No contact with overheating sensor. Check ribbon cable.
E4: Faulty room sensor. Contact dealer.
Technical specifications:
Manufacturer:……………………………………… Sikom AS, Norway
Article numbers………………………………….……….……64 014 00
Article name ……………………………… Eco Thermostat SI-4 10A
Operating temperature:………………….………………. 0 C to +45 C
Power supply:……………………………………………….… 230 VAC
Radio:…………………………………….……… …433.9 MHz , 10mW
Max load:………………………………………………………………10A
Regulation:…………………………………..…… P-regulator. 0-100%
Regulation range:……………………………………..…. 5 C to +40 C
Measurement range:………………………………….…. 0 C to +45 C
Approval:………………………………………….………………….. CE
Hereby, Sikom AS declares that the radio equipment type Eco
Thermostat SI-4 10A is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: www.sikom.no
Contact information
Sikom AS
Phone: +47 740 85 960
Neptunveien 6
E-mail: [email protected]
N-7652 Verdal, Norway
Web:
www.sikom.no
64 014 00 Monteringsanvisning Termostat SI-4 10A Nor-Eng Rev1.0