Siko MSAC200 Скачать руководство пользователя страница 2

Quick Start Guide

MSAC200, MRAC200  ·  Date 23.02.2022  ·  Art. No. 90821  ·  Mod. status 195/21

SIKO GmbH

Weihermattenweg 2
79256 Buchenbach

www.siko-global.com

Phone

: + 49 7661 394-0

Fax

: + 49 7661 394-388

Service

: [email protected]

MSAC200_MRAC200

Magnetic sensor

For detailed documentation please refer under  

http://www.siko-global.com/p/msac200 

http://www.siko-global.com/p/mrac200 

General information

Prior to installation, including in hazard areas, read the Installation Instruc-
tion (download from the internet). It contains the safety instructions, hints 
and technical data to be observed during installation. Subject to change with-
out notice.

 Caution

In order to ensure reliable functioning of this product, take care to transport, 
store, position and mount it appropriately. Exercise care when you operate and 
maintain the device. Only properly qualified personnel are authorized to install 
and operate this product.

Safety information

It is important for safety reasons that you read and understand the below 
instructions before you install the system:

• 

Installation, connection, commissioning and maintenance shall be done by 
properly qualified personnel.

• 

It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of 
the Installation Instruction.

• 

It is the responsibility of the customer to ensure that the magnetic sensor is 
correctly connected and configured.

• 

Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.

Mounting the magnetic ring

The magnetic ring MRAC200 must be mounted on the customer shaft without 
tension with cylinder head screws ISO4762 (see table).

• 

A sliding fit must be provided between the customer shaft and the MRAC200.

• 

The MRAC200 magnetic ring must be mounted as free of force and tension as 
possible. Any necessary loads must be applied to the metal flange. Impacts 
on the magnetic ring must be avoided. 

9

1

10

2

Mounting magnetic sensor

 Caution

Alignment of the magnetic sensor  
Take care that the magnetic sensor is aligned correctly in order to ensure opti-
mum sensing

• 

Mount magnet encoder MSAC200 stressfree with cylinder head screws ISO 
4762, see table. 

• 

Align the reading head with the magnetic ring over the elongated holes 
using the distance gauge. 

• 

Attach the electronic unit using the 3 holding plates.

1

2

Electrical installation

SSI pin assignment

JST SM10B-GHDS-A-GAN-TF

Pin

Signal

Description

1

B

Positive quadrature output

2

/B

Inverted quadrature output

3

A

Positive quadrature output

4

/A

Inverted quadrature output

5

T-

SSI clock input -

viewing side = plug-in side

9

1

10

2

Pin

Signal

Description

6

D-

SSI data -

7

T+

SSI clock input +

8

D+

SSI clock input +

9

+UB

Operating voltage encoder

10

GND

Encoder ground connection  

BiSS C Pin assignment

JST SM10B-GHDS-A-GAN-TF

Pin

Signal

Description

1

B

Positive quadrature output

2

/B

Inverted quadrature output

3

A

Positive quadrature output

4

/A

Inverted quadrature output

5

NMA

BiSS C - clock input -

6

NSLO

BiSS C - data -

7

MA

BiSS C - clock input +

8

SLO

BiSS C - Daten +

9

+UB

Operating voltage encoder

10

GND

Encoder ground connection 

 0.1 ... 0.6 

1

  

3

±0.5

°

 1.25 

±0.5

 

4

>>>

>>>

2

1

 

Distance ring / encoder direction

2

 

of rotation positive

3

 

Permissible angular offset ring / encoder

4

 

distance stop surface ring / encoder

viewing side = plug-in side

9

1

10

2

Отзывы: