1 2
MA03/1
Datum 08.01.2002
Art.Nr. 79474
Z.Nr. 8664074
Änd.Stand 389/01
Display Designation / value range
Standard programm.
your programming
_rES_
resolution (mm, In=inch)
0.1
1, 0.1, 0.05, 0.01, In 0.01, In 0.001,
FrEE
_FAC_
calculation factor (only if resolution
0.00000
has been programmed to "FrEE")
0.00001 ... 9.99999
_rEF_
reference value
00000.0
-999999 ... (+)999999
_oFF_
offset value -999999 ... (+)999999
00000.0
_dP_
decimal point (only if resolution has
0.0
been programmed "FrEE") 0. to 0.000
_dIR_
counting direction UP, dn
UP
_AUto_
switch-off method on, oFF
oFF
PErIod
switch-off time (in minutes)(only for
009
switch-off methods 'on') 009... 999
_rSTo__ last value memory on, oFF
oFF
_4_oFF Delayed switch-off : on, oFF
oFF
_F_AbS access reset function: on, oFF
on
_F_rEL
access increm. measurement:
oFF
on, oFF
_F_rEF
access reference value:
oFF
on, oFF
_F_oFF access offset value:
oFF
on, oFF
_SPEEd Processor speed: HI , Lo
HI
_LAn_
language d, E
d