
Quick Start Guide
LEC160 · Date
14.05.2019 · Art.
No.
89972 · Mod.
status
94/19
SIKO GmbH
Weihermattenweg 2
79256 Buchenbach
www.siko-global.com
Phone
: + 49 7661 394-0
Fax
: + 49 7661 394-388
Service
LEC160
Magnetic sensor
For detailed documentation please refer under
http://www.siko-global.com/p/lec160
General information
Prior to installation, including in hazard areas, read the Installation Instruc-
tions (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
•
Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
•
It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation Instructions.
•
It is the responsibility of the customer to ensure that the magnetic sensor is
correctly connected and configured.
•
Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
Mounting of the magnetic sensor
The sensor senses the incremental travel information of the MB160 magnetic
tape.
The LEC160 magnetic sensor is mounted by two screws M3.
Mounting the magnetic tape
Stick the magnetic tape level to the mounting surface or the distance to be
measured. Unevenness impairs measuring accuracy.
Mounting steps:
•
Clean mounting surface
1
carefully.
•
Remove protective film
2
of the adhesive tape
3
.
•
Stick down the magnetic tape
4
.
•
Clean surface of magnetic tape carefully.
•
Remove protective film
6
of the cover tape
5
.
•
Fix cover tape (both ends should slightly overlap).
•
Also fix cover tape's ends to avoid unintentional peeling.
4
6
1
2
3
5
Notice!
The tolerance and gap measures must be observed over the whole measuring
length.
LINEAR application
10
Position of the reference point P = as
stated in the delivery documentation
Position of the reference point E = as stated
in the delivery documentation; ≥0.01 m
Magnetic poles -
schema
Unique reference point
Periodical reference point
MBxxxx GEK WT RP NNNNNN
Position of the reference point relating
to the marking on the magnetic tape
0.
1 ... 0.8 mm
O, I r
efer
ence signal
0.
1 ... 0.5 mm
R r
efer
ence signal
0.4 ... 0.6 mm
FR r
efer
ence signal
Gap sensor/magnetic tape
<1°
<3°
active
side
Direction
of outgoing
cable
Travel direction
signal
sine before cosine
or A before B
Maximum alignment error
<3°
Admissable deviation
middle of tape/sensor:
±0.5 mm
flexible reference mark
Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the sensor or the connection lines!
•
All lines for connecting the magnetic sensor must be shielded.
•
Wiring to the screen and ground (0 V) must be secured to a good point.
Ensure that the connection of the screen and earth is made to a large sur-
face area with a sound connection to minimise impedance.
•
When mounting the system keep a maximum possible distance from lines
loaded with interference. Use screening shields or metallized housings.
•
Contactor coils must be linked with spark suppression.
Color assignment of the open cable end
Color
Interface 1Vss
Signal
Interface LD
Signal
red
sin
A
yellow
cos
/A
blue
index
I, R, FR
brown
+UB
+UB
black
GND
GND
orange
/sin
B
green
/cos
/B
violet
/index
/I, /R, /FR
Technical data
Electrical data
Sin/cos output
Additional information
Operating voltage
5 V DC ±5 %
reverse polarity protected
Current consumption <35 mA
off-load
<50 mA
loaded
Electrical data
LD output circuit
Additional information
Operating voltage
5 V DC ±5 %
reverse polarity protected
Current consumption <50 mA
off-load
<120 mA
loaded