IKM360R
Inclinometer
For detailed documentation please refer under
http://www.siko-global.com/p/ikm360r
General information
Prior to installation, including in hazard areas, read the Installation Instruc-
tion (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
•
Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
•
It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation Instruction.
•
It is the responsibility of the customer to ensure that the inclinometer is
correctly connected and configured.
•
Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
Mechanical mounting
The IKM360R is a pre-calibrated instrument that can be put into operation
immediately. The mounting area must be level, free from dust and grease. Use 3
pieces of M5 cylinder head screws and washers for fastening. Ensure a uniform
bolt tightening torque of 4.5 Nm. Take care to mount the inclinometer free from
distortion.
The side with the marked axes and the identification plate is the inclinometer's
upper side.
Z = 0°
Number of axis 1
Initial starting point
(factory settings)
Y = 0°
-Y
+Y
X = 0°
-X
+X
Number of axis 2
X-axis
Y-axis
Mounting instructions
Please handle the inclinometer carefully. Especially do not:
•
Disassemble or open the inclinometer.
•
Knock on casing; the inclinometer's inner components could be damaged.
Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the inclinometer or the connection lines!
•
All lines for connecting the inclinometer must be shielded.
•
Never wire or disconnect electrical connections while they are live.
•
Perform wiring work in the de-energized state only.
•
Use strands with suitable ferrules.
•
Ground (GND) nust be connected with the protective earth conductor (PE).
•
Wiring to the screen and ground (GND) must be secured to a good point.
Ensure that the connection of the screen and earth is made to a large sur-
face area with a sound connection to minimise impedance.
•
Check all lines and plug connections before switching on the device.
•
When mounting the system keep a maximum possible distance from lines
loaded with interference. Use screening shields or metallized housings.
Pin assignment
Signal
PIN E12 + E12E
nc
1
+UB
2
GND
3
CAN_H
4
CAN_L
5
Technical data
Electrical data
Additional information
Operating voltage
8 … 36 V DC
reverse-polarity protected
Current consumption ≤100 mA
without load
viewing side = plug-in side
E12: Bus OUT Bus IN
2
5
4
3
1
2
5
4
3
1
viewing side =
plug-in side
E12E: Bus IN
2
5
4
3
1