4.5.4
Display String Mode
In the
alphanumeric display
mode, this parameter selects the data source for the display.
The Display String Mode = 1 is set to display Display String1 and Display String2. This is only
possible when the data type ASCII is active; for this purpose, Bit7 = 1 or Bit8 = 1 must be set
in the control word. As a result, it is possible to display 6 ASCII characters per line.
Otherwise, the Target Value process data and Display Data are displayed.
General characteristics
EEPROM
yes
Class
V
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0057d / 39h
Web server
57
Display
Menu
Data type Unsigned8
Value range
0 … 1
Default
0 (default)
Parameter selection
Value
Description
0
Target Value process data and Display Data are used as display value.
1
Display String1 and Display String2 are shown on the display.
4.5.5
Display String1
Data contents Line 1 with active display string mode.
General characteristics
EEPROM
no
Class
V
Unit
-
PROFINET
Data type
Unsigned32
Access
Get/Set
Instance
0058d / 3Ah
Web server
58