Parameters
AP20S
Date: 24.08.2020
Art. No. 89992
Mod. status 133/20
Page 57 of 79
4.5.18
CODE Input
The code can only be entered on the device. Either via the parameter menu options or with
Key Configuration is the key is locked.
General characteristics
EEPROM
no
Class
-
Unit
-
PROFINET
Data type
Integer32
Access
Set
Instance
-
Web server
-
Display
Menu
CODE
(
chPARA
\
OPTION
\
CODE
)
Data type Integer32
Value range
0 … 999999
Default
0 (default)
Parameter selection
Value
Display
Description
100
000100
Start alignment process
11100
011100
Reset, all parameters
11102
011102
Reset, all, except interface parameters
11105
011105
Reset, interface parameters only
4.5.19
Generic Mapping Parameter
This parameter defines the content of the generic mapping channel, which is part of the
process data.
General characteristics
EEPROM
yes
Class
N
Unit
-
PROFINET
Data type
Unsigned8
Access
Get/Set
Instance
0012d / 0Ch
Web server
12