2.4 Basic safety information
Danger of explosion
`
Do not use the actuator in explosive zones.
Unbraked actuator
Immediate loss of torque in case of voltage breakdown, interference and
activation of the output stage/control unit supply. The actuator will not be
braked.
`
Use external stopping devices (e. g. EMERGENCY-STOP holding brake).
Rotating parts
Bruising, rubbing, abrasing, seizing of extremities or clothes by touching
during operation any rotating parts as for example clamping ring, torque
support or hollow shaft.
`
Prevent people from access by installing protective facilities.
Hot surfaces
Burns by temperatures >60 °C on the housing during operation.
`
Prevent access to the housing.
`
Protect temperature-sensitive parts of equipment using guards.
Residential environment
High frequency interference in residential areas.
`
This actuator is not suitable for use in a public low voltage system as
those common in housing area.
High energetic recovery
In case of high moment of inertia in the customer plant and simultane-
ous braking, the actuator may switch over to generator operation; i. e.,
mechanical energy will be converted into electrical energy and fed back
into the mains. The power supply unit must be able to absorb the develop-
ing energy to avoid destruction of other electric consumers.
`
Use only power supply units with a high output capacitance
(>10.000 µF) or power supply units capable of recovering energy.
`
Use an appropriate brake resistor control if required.
`
Check that all consumers are designed to absorb energetic recovery
voltage.
External magnetic fields
Failures and data loss occur if strong magnetic fields influence the internal
measuring system.
`
Protect the actuator from impact by external magnets.