AG03/1
Installation English
AG03/1 · Date
30.05.2022 · Art.
No.
86426 · Mod.
status
116/22
38
Fig. 2: Mounting
3
Fig. 3: Shaft with
clamp collar
Fig. 4: Shaft with
feather key groove
4
5
1
Torque support form A
2
Torque support form B
3
Shaft
4
Champ ring screw
5
Grub screw
4.2 Electrical Installation
Electric shock caused by wrong power adapter
`
Use a power adapter which complies with the requirements of PELV
(Protective Extra Low Voltage).
`
Connect the negative output of the power adapter to PE.
`
Connect to the actuator only those downstream electronic units,
whose operating voltage is generated by PELV systems.
Destruction of parts of equipment and loss of regulation control
`
Do not disconnect or close live connections.
`
Perform wiring work in the de-energized state only.
`
Use strands with suitable ferrules.
`
Prior to switching on check all mains and plug connections.
`
Switch on operating voltage together with downstream electronics (e.
g., control unit).
Unforeseen actions of the actuator or other devices
The actuator is protected against EMC irradiation and emission (electro-
magnetic compatibility). Excessive external EMC radiation may trigger
unforeseen actuator actions (including destruction of the actuator; the
actuator being set in motion; loss of position value) Devices that are not
EMC protected and those operated in direct vicinity to the actuator may be
disturbed.
WARNING
WARNING
DANGER