About this operating manual  

Technical changes reserved 

 

- 3 -

 

0

 

About this operating manual 

 

 

The operating manual is aimed at specialists and semi-skilled personnel. 

 

Before each step, read through the relevant advice carefully and keep to the specified 
order. 

 

Thoroughly read and understand the information in the section "Safety instructions". 

 

If you have any problems or questions, please contact your supplier or contact us directly 
at: 

 

 

 

 

Dr. Siebert & Kühn GmbH & Co. KG 

Struthweg 7-

9 • D 

34260 Kaufungen

 

 

05605

-

803 0 • 

 

05605

-

803 54

 

info

@

sika

.net • www.

sika.net 

 
 
 

Hazard signs and other symbols used: 

 

WARNING! / CAUTION! Risk of injury! 
This sign indicates dangers that cause personal injuries that can lead to health defects or 
cause considerable damage to property. 

 

CAUTION! Electric current! 
This sign indicates dangers which could arise from handling of electric current. 

 

CAUTION! Material damage! 
This sign indicates actions which could lead to possible damage to material or environmental 
damage. 

 

ADHERE TO OPERATING MANUAL! 
 

 

NOTICE!  
This symbol indicates important notices, 
tips or information. 

 

NO DOMESTIC WASTE! 
The device must not be disposed of to-
gether with domestic waste. 

 

 

  Pay attention to and comply with infor-

mation that is marked with this symbol.  

  Follow the specified instructions and steps. 

Adhere to the given order. 

  Check the specified points or notices.  

  Reference to another section, document or 

source. 

  Item. 

 
 
 

Содержание induQ VMZ 030

Страница 1: ...f the device is resold please provide the operating manual along with it SIKA Ba_VMZ_en 05 2016 Magnetic Inductive Flow Sensor Series VMZ Types VMZ 030 VMZ 081 VMZ 082 VMZ 153 VMZ 204 VMZ 205 VMZ 256...

Страница 2: ...and off 11 6 3 Measuring operation 11 7 Maintenance and cleaning 12 7 1 Return shipment to the manufacturer 12 8 Disassembly and disposal 13 9 Technical data 14 9 1 Characteristics VMZ 14 9 2 Material...

Страница 3: ...CAUTION Risk of injury This sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property CAUTION Electric current This sign indicates da...

Страница 4: ...n the front of the VMZ It contains the most important data and the connection dia gram for the electrical connection Example Fig 1 1 Delivery unpacking and accessories All units have been carefully ch...

Страница 5: ...device supplied is only guaranteed by intended use The speci fied limits 9 Technical data may under no circumstances be exceeded Before installing the device check that the wetted materials of the de...

Страница 6: ...must be aware of this operating manual and have access to it at all times The electrical connection should only be carried out by a fully qualified electrician General safety instructions In all work...

Страница 7: ...el electrodes are located in the middle of the measuring tube between the earthing sleeves The VMZ does not need any moving parts to make measurements The inside of the measur ing tube is completely o...

Страница 8: ...e equipment is depressurised and has cooled down SUITABLE TOOLS Use only suitable tools of the correct size 4 1 Installation instructions CAUTION Risk of malfunction due to external magnetic fields Ma...

Страница 9: ...adjacent devices If adjacent devices are too close together operation of both devices may be impaired due to mutual interference 4 2 Assembly The VMZ is installed directly into the pipeline The compa...

Страница 10: ...ize the electrical system before connecting the VMZ Connection and wiring Screw the coupling socket of the connection cable to the plug of the VMZ Tighten the knurled nut of the coupling socket with a...

Страница 11: ...annot be switched on or off on its own Switching on and off is carried out by the applied supply voltage Switch on the supply voltage The red LED lights up permanently The VMZ is ready for use and goe...

Страница 12: ...he operating company WARNING Risk of injury due to insufficient cleaning The operating company is responsible for all damages and harm of any kind in particu lar physical injuries e g caustic burns or...

Страница 13: ...r to disassembly ensure that the equipment is switched off and is in a safe and de energised state the equipment is depressurised and has cooled down Disassembly Remove the electrical connectors Remov...

Страница 14: ...10 0 12 5 Signal shape Square wave signal duty cycle 50 50 can be connected as PNP or NPN open collector Signal current 25 mA Electrical characteristics Supply voltage 24 VDC 15 or 12 VDC 15 Power co...

Страница 15: ...nt Material Component wetted Housing ABS Measuring tube VMZ_ _ _ _ _DE_ _ _ _ _ _ VMZ_ _ _ _ _PE_ _ _ _ _ _ POM PVDF X Process connections VMZ_ _ _ _ _DE_ _ _ _ _ _ VMZ_ _ _ _ _PE_ _ _ _ _ _ POM PVDF...

Страница 16: ...Technical data induQ Series VMZ 16 SIKA Ba_VMZ_en 05 2016 9 3 Pressure drop...

Страница 17: ...l data Technical changes reserved 17 9 4 Dimensions VMZ DN 3 DN 8 DN 15 DN 20 Type L1 L2 D1 D2 VMZ 030 85 13 3 G B 3 VMZ 081 85 13 3 G B 8 VMZ 082 85 13 3 G B 8 VMZ 153 90 16 G B 14 VMZ 204 90 16 G1 B...

Страница 18: ...Technical data induQ Series VMZ 18 SIKA Ba_VMZ_en 05 2016 VMZ DN 25...

Страница 19: ...induQ Series VMZ Technical changes reserved 19 For your notes...

Страница 20: ...05 2016 Sensors and Measuring Instruments Flow Measuring Instruments Test and Calibration Instruments SIKA Dr Siebert K hn GmbH Co KG Struthweg 7 9 D 34260 Kaufungen Germany 49 0 5605 803 0 49 0 5605...

Отзывы: