Instruction Manual OilGuard 2 W
Electrical installation
28
14809E/2
The front cover must first be removed from the OilGuard 2 W according to Section 5.2. Es-
tablish the electrical connections in the following sequence:
TERMINALS
MEANING
REMARKS
1.
1 – 2 – 3
Output 1
(relay contact 1)
The relay contacts can be freely con-
figured.
2.
4 – 5 – 6
Output 2
(relay contact 2)
3.
18, 19
Current output 1
0/4 .. 20 mA
4.
20, 21
Current output 2
0/4 .. 20 mA
5.
22, 23
Connection for optional
flow rate monitoring
Use the small cable gland (X).
6.
7 – 8 – 9
18 – 30 VDC power supply Use the cable gland (Y) in the mid-
dle.