![Sigrand SG-16G Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/sigrand/sg-16g/sg-16g_user-manual_1269429029.webp)
: e1 code ami
E1A: Long-Haul FRAMED CRC4 CAS Code=AMI – ONLINE
: e1 code hdb3
E1A: Long-Haul FRAMED CRC4 CAS Code=HDB3 – ONLINE
:
ITU-T G.703 recommendation requires the HDB3 line coding.
3.4.4 Е1 interface statistics
Use the
е1
command with the
stat
option to view the statistics:
: e1 stat
E1A: Long-Haul FRAMED CAS Code=HDB3 – ONLINE
FAS_Sync=No CAS_Sync=No
CV=0 FASE=0
Loop Loss: 37.5 dB
:
FAS_Sync
–
framing synchronization status;
CAS_Sync
–
CAS superframe synchronization status;
CRC4_Sync
–
CRC4 superframe synchronization status;
CV
– the number of code violations
FASE
–
the number of Frame Alignment Signal Errors
CRC4E
–
the number of CRC4 errors
E-bits
–
the number of far end errors;
Loop Loss
– line loop loss, dB;
Execution of the
e1 stat
command does automatic reset of any
current statistics of the interface!