Sigrand IPhouse-15E/IR Скачать руководство пользователя страница 12

The 

fan auto

 command enables the automatic controlling the fans. In this mode the fans are turned on or 

off automatically along with the LEDs. It is the default setting.

:fan auto

The 

fan on

 command turns the fans on. In this mode the fans are not turned off when the LEDs are off.

:fan on

The 

fan off

 command turns the fans off.

:fan off

Note: Do not turn the fans off unless the LEDs are turned off too. Disabling the fans can cause overheat  

of the LEDs.

The 

fan save

 command saves the fans settings to the EEPROM.

:fan save
OK

5.5.7 Ambient Temperature Monitoring – 

temp

The 

temp

 command displays the ambient temperature (in 

°C

).

:temp
+24.5'C

5.5.8 Illuminance Monitoring – 

lux

The 

lux

 command displays the illuminance (in 

lux

)

:lux
20 lx

Note: the illuminance reading highly depends on the placement of the illuminance sensor. For correct 

reading, the sensor should be directed to the source of light.

5.5.9 Total Power Monitoring – 

power

The 

power

 command displays the total power consumed by the device (including the camera).

:power
V=50.9V I=181mA P=9.23W

The command displays three parameters.

The 

V=

 parameter is the PoE voltage.

The 

I=

 parameter is the total current drawn from the PoE network.

The 

P=

 parameter is the total power consumed from the PoE network.

Note:   The   parameters   are   shown   from   the   powered   device's   point   of   view.   The   power   sourcing 

equipment's readings can be higher due to some power loss in the cable.

5.5.10 Restoring Factory Settings – 

default

The 

default

 command resets all settings to their default values (see Table 4). Press the 

y

 key to confirm 

the operation or the 

n

 key to cancel it.

:default
Load defaults? (y/n):y
Default settings loaded.

5.5.11 Restarting the Device – 

reboot

The 

reboot

 command causes the restart of the device. The camera is restarted as well.

:reboot
Rebooting...
Sigrand IPhouse-15 Light Camera Housing V.2.0
Ready!

Note: The SSH connection  to the camera will  be  lost.  The new connection is  not possible until  the 

camera's boot process completes.

5.6 Troubleshooting

5.6.1 Settings Not Saved

12

Содержание IPhouse-15E/IR

Страница 1: ...nal and external temperature as well as remote power feeding parameters The IPhouse 15 is controlled by the Command Line Interface CLI The IPhouse 15 can be supplied in several configurations IPhouse...

Страница 2: ...op Table 5 PoE Characteristics Recommended Parameter Value Units Total Power Consumption max 15 W PoE Class 3 Camera Power Consumption max 7 W Camera PoE Class 2 Table 6 Default Settings Parameter Val...

Страница 3: ...support 4 1 4 Attach the support to the camera by means of the nut and the screw 1 4 1 5 Insert the camera into the housing and fix it by the thumbscrews 4 2 Serial Port Connection 4 2 1 If the camer...

Страница 4: ...short Ethernet patch cord 4 5 PoE Chain LAN Connection A camera with two Ethernet ports and PoE chain capability should be used to make a PoE chain The housing has no PoE chain capability itself In s...

Страница 5: ...ng temperature and illuminance On Off thresholds Monitoring temperature illuminance and consumed power Accessing by SSH through camera s serial port or by a terminal 5 2 Accessing CLI through Camera s...

Страница 6: ...IPhouse 15 Console Cable Annex A to the console port of the IPhouse15 device XP7 Attach DB 9F connector of the Cable to the COM port of your PC 5 3 2 Setting up HyperTerminal Run the HyperTerminal Pro...

Страница 7: ...st command can be edited 5 4 4 Error Messages If the entered command is not a valid command the device answers with the Unknown command message abcd Unknown command If the command has arguments and on...

Страница 8: ...emperature sensor 5 5 2 2 Controlling LEDs The LEDs can be controlled manually of automatically The commands led on and led off are intended for the manual control The led on command turns on the LEDs...

Страница 9: ...tting of the power backoff led pbo 50 Warning Changing these setting may affect the LEDs lifetime 5 5 2 6 Saving LEDs Settings The led save command writes the current LEDs settings to the EEPROM led s...

Страница 10: ...d It allows the camera to avoid operating at the temperature which is out of the camera s ratings Note Preheat is not functional in the PoE chain configuration and should not be enabled 5 5 4 1 Prehea...

Страница 11: ...ng is not functional Icam and Icam are always 0 5 5 5 2 Controlling Camera The cam auto command enables the automatic controlling the camera The automatic mode is used only for the preheat feature see...

Страница 12: ...nitoring power The power command displays the total power consumed by the device including the camera power V 50 9V I 181mA P 9 23W The command displays three parameters The V parameter is the PoE vol...

Страница 13: ...olution 1 Disconnect the camera or the LEDs physically to allow the device to start successfully Reduce the power settings or restore the default settings by the default command Connect back the camer...

Страница 14: ...6 Annex A Table 7 IPhouse 15 Console Cable Pinout BLS 2 IPhouse 15 Pins Network DB 9F COM port Pins 1 TXD 3 2 RXD 2 3 GND 5 4 DTR 4 14...

Отзывы: